Mechanical Setup and Installation
DYACON Quick-start Guide
3.1.3 Set Vane North Position
Press
Select
will enable Setup mode.
Press ▼ (Down) until Wind Dir is seen.
>Setup Wind Dir
Press
Select
to enter the Set New North configuration.
>Set New North
Manually hold or tape the vane in the desired position
(magnetic or grid north, depending the
application.
Press
Select
to set the position as 0 degrees.
North Set
Continue holding the vane in the north position to validate the setting.
The display will show “North Set” momentarily, then return to the configuration page.
>Set New North
Clear Setting
Pressing
Cancel
twice will exit Setup mode and return to Acquisition mode.
By paging down one position, users will see the direction. The wind direction should show a
value near 0 or 360 deg.
Acquisition page after setting north.
1.2 m/s @ 0.1 deg
Gust: 0.0 st: 0
Page 10/22