PMC-700-X00 User’s Manual
DY 4 Systems Inc.
3-10
809789 Revision 2 December 2000
Apply Power
Power up the chassis.
Immediately after the chassis is powered on, the red FAIL LED and green
STATUS LED come on.
Once the basecard passes its initial diagnostics, the Card Level Diagnostics
(CLD) routines turn the red FAIL LED off. If the CLD routines detect a failure,
the red FAIL LED stays on. In either case, the green STATUS LED stays on.
The two green LEDs on the PMC-700 front panel should be lit, indicating that
the PMC-700-X00 has 3.3 V and 2.5 V power.
Cross
Reference
For additional information on the power-up sequence, refer to Chapter 3 of the
Getting Started Manual for your basecard.
Cross
Reference
If the red FAIL LED on the basecard stays on after power-up, then the CLD
suite found one or more problems. Refer to “TroubleShooting” in your
basecard Getting Started Manual for information about locating the problem.
Display the GPM
Prompt
Press any key on the terminal keyboard to display the initial screen message.
The initial screen message shows the card’s VME base address, which should
be 4000 0000 if the card is installed in Slot 1.
Cross
Reference
For information on the General Purpose Monitor (GPM), refer to Chapter 6 of
the FFW User’s Manual (808006).