DY 4 Systems Inc.
Hardware Installation on a DY 4 PowerPC™ Basecard
809789 Revision 2 December 2000
3-9
PMC-700-X00 is in PMC
Slot 1
If the PMC-700-X00 is installed in PMC slot 1, use the P0 interface (as shown
in Figure 3.2 on page 3-6), to connect a monitor. The mapping of signals
between the basecard P0 connector and the DVI and VGA connectors on the
CBL-700-001 is shown in Table 3.3.
Table 3.3:
Signal Mapping from Basecard P0 Connector to Video Connectors
P0 Pin
Signal Name
DVI Pin
VGA
Connectors
E4
TXC-
24
C4
TXC+
23
A4
GND
22
D4
TX0-
17
B4
TX0+
18
E5
GND
19
A13
TX1-
9
B13
TX1+
10
C13
GND
11
E19
TX2-
1
C19
TX2+
2
B18
GND
3
A14
FPDDCCLK
6
D15
FPDDCDATA
7
B19
CRT_GREEN
2
D19
CRT_GREEN_ RTN
7
E18
CRT_BLUE
3
B17
CRT_BLUE_RTN
8
A18
CRT_RED
1
C18
CRT_RED_RTN
6
E16
CRT_HSYNC
13
B15
CRT_HSYNC_RTN
5
C16
CRT_VSYNC
14
A16
CRT_VSYNC_RTN
10