OPM BWT PERMAQ® Pico Rev. 2.0 EN
Technical data | 10
EN
55
10.7 Technical data for the BWT PERMAQ® Pico Vario 40-90
(HR)
40 / 50 / 60
40 HR / 50 HR / 60 HR
70 / 80 / 90
70 HR / 80 HR / 90 HR
Permeate:
Min. online output,
3.0
bar counter pressure
1)
l/h
150 / 250 / 350
100 / 180 / 220
700 / 960 / 1100
600 / 750 / 900
Max. online output,
3.0
bar counter pressure
2)
l/h
450 / 900 / 1250
400 / 750 / 10000
1600 / 1750 / 2100
1050 / 1400 / 1700
Min. online output,
7.0
bar counter pressure
1)
l/h
30 / 120 / 150
60 / 60 / 100
280 / 300 / 350
250 / 270 / 300
Max. online output,
7.0
bar counter pressure
2)
l/h
360 / 750 / 110
280 / 560 / 700
1550 / 1900 / 2050
1050 / 1400 / 1700
Salt retention rate
%
> 98.5
> 99.0
Permeate yield WCF
%
80
80
Feed water:
Pressure range
bar
2.5 - 6.0
2.5 - 6.0
Temperature range
°C
5 - 30
5 - 30
Hardness / with antiscalant dosing
°dH
°fH
0.0 / 25
0.0 / 45
0.0 / 25
0.0 / 45
Iron (Fe) and manganese (Mn)
mg/l
< 0.1
< 0.1
Salt content, total dissolved solids (TDS) mg/l
< 1’000
< 1’000
Silt density index (SDI)
%/min
< 3
< 3
Oxidants
mg/l
< 0.05
< 0.05
Silicate (SiO
2
)
mg/l
< 20
< 20
Hydraulic connections:
Feed water
inch
¾“
1“
Permeate
inch
¾“
1“
Concentrate
mm
13mm / FT version 8mm 13mm / FT version 10mm
General:
Protection class
IP
63
IP
63
Ambient temperature
°C
5 - 35
5 - 35
Electrical connection / fuse protection
V/Hz/A
400/50/10
400/50/10
Electric power consumption
kW
1.6/2.2/2.2
1.6/2.2/2.2
3.1/3.1/3.1
3.1/3.1/3.1
Type of valve
VDC
24
24
Connector standard
CEE 16; 3PNE
CEE 16; 3PNE
1)
Feed water: TDS ≤ 1’000 mg/l; 15 °C; 2.5 bar
2)
Feed water: TDS ≤ 1’000 mg/l; 15 °C; 4.0 bar
Table
20: