Configuration and Installation
2-13
Alarms
The mini dome cameras can generate and receive alarms.
The mini dome camera has two alarm inputs and one relay output terminals. A typical configuration
requires you plug an event sensor to the input 1 and ground I/O terminals on the Pro Line 9460A
camera, and your alarm system to the Out section of a receiver.
You can activate the alarm process via iSOC NVMS.
Updating the Firmware
You can update the firmware of the Pro Line 9460A mini dome cameras with the
Device Configurator
tool. For the detailed procedure, refer to the documentation of the
Device Configurator
.
The only method to update the firmware is through an IP network connection. If this update
procedure fails, repeat procedure.
Take the following facts regarding firmware update using the IP network into consideration:
•
Ensure that the IP link is stable before starting the procedure; therefore it is not recommended to
perform it over the Internet.
•
Ensure that the power supply is stable before starting the procedure and do not disconnect it
during the procedure.
Red/Blue Display
If Pro Line 9460A
mini dome cameras currently streaming video to a management software lose their
connection to a mini dome camera, the corresponding display tile in the software will present a half
red, half blue pattern.
The red/blue display is an indication of a bad mini dome camera or connection to the mini dome
camera. It may also occur if the unit is under powered or there is low voltage.
Summary of Contents for Pro Line 9460A
Page 1: ...Pro Line 9460A Vandal Resistant Mini Dome User s Manual October 13 2008...
Page 8: ...Pro Line 9460A User s Manual 1 4...
Page 22: ...Pro Line 9460A User s Manual 2 14...
Page 32: ...Pro Line 9460A User s Manual 3 10...
Page 50: ...Pro Line 9460A User s Manual 4 18...
Page 52: ...Pro Line 9460A User s Manual A 2...