DVP LB.40WR Operating And Maintenance Instructions Manual Download Page 8

 

Operating and Maintenance Instructions

 

 

LB.5WR – LC.25WR – LB.40WR – LB.60WR – LC.105WR

 

EN 

 

 

www.dvp.it 

8702037 – 01/01/2011 – R.0 

 

 

3.3.2 

Model:  LC.25WR 

 

Oil filler plug

Oil sight

glass

Terminal

board

Level switch

Oil

viewer

Motor fan

guard

Attachment

point

Attachment

point

Oil drainage

valve

Motor

rating

plate

Information

plate

Intake

Air

outlet

M8

Only on "FKM" versions

 

 

LC.25WR 

TECHNICAL SPECIFICATIONS 

50 Hz 

60 Hz 

Inlet capacity 

m³/h 

25 

29 

Final pressure (Abs.) 

mbar - hPa 

Max inlet pressure for water vapour 

mbar - hPa 

50 

Max water vapour pumping rate 

Kg/h 

0,9 

Motor power 

kW (1

~

 / 3

~

0,75 / 0,75 

0,90 / 0,90 

Nominal r.p.m. 

n/min 

1400 

1700 

Noise level (UNI EN ISO 2151) (K 3dB) 

dB(A) 

62 

65 

Weight 

kg (1

~

 / 3

~

26,5 / 25,5 

Type of oil 

cod. DVP 

SW60 (BV68)

 

Oil quantity 

Min÷Max dm³ 

0,8 ÷ 1,1 

Pump Intake / Outlet 

“G 

1/2  /  1/2 

Continuous-duty working renge (Abs.) 

mbar - hPa 

400 ÷ 2 

Operating temperature (room temp. 20°C) 

°C 

80 ÷ 85 

85 ÷ 90 

Required room temp. for place of installation 

°C 

12 ÷ 40 

Ambient temperature for storage/transport 

°C 

-20 ÷ 50 

MAX humidity / altitude 

 

80% / 1000m a.s.l.  * 

(*)  Please contact the Manufacturer if environmental conditions are different from those prescribed. 

Summary of Contents for LB.40WR

Page 1: ...TECHNOLOGY OPERATING AND MAINT ENANCE INSTRUCTIONS Translation of the original instructions VACUUM PUMPS WITH RECIRCULATING LUBRICATION SYSTEM LB 5WR LC 25WR LB 40WR LB 60WR LC 105WR www dvp it info...

Page 2: ...entele to reach its objectives For this reason our customers are the focus of our attention and we promote the sending of suggestions and or proposals for improvements that could be applied to our pro...

Page 3: ...AND HANDLING 9 4 4 STORAGE 9 4 5 ENVIRONMENTAL CONDITIONS 9 4 6 PUMP INSTALLATION 10 4 7 MOTOR INSTALLATION ONLY LC 105WR 10 4 8 USER SYSTEM 10 4 9 CONNECTION 10 4 9 1 ASSEMBLING THE INTAKE FILTER ON...

Page 4: ...model and serial number year of manufacture date of purchase detail information regarding problems verified 1 3 METHOD OF CONSULTATION For improved understanding of the information provided in this ma...

Page 5: ...other identification plaques D V P Vacuum Technology S r l disclaims any liability for damage to persons or property resulting from improper use of the pump from tampering with its safety apparatus o...

Page 6: ...mps are designed specifically to work with clean air and inert gases in atmospheres with a high amount of water vapour Any other use is prohibited The Manufacturer is not liable for any damage to pers...

Page 7: ...capacity m h 5 6 Final pressure Abs mbar hPa 10 Max inlet pressure for water vapour mbar hPa 30 Max water vapour pumping rate Kg h 0 11 Motor power kW 1 3 0 25 0 37 0 25 0 45 Nominal r p m n min 1400...

Page 8: ...2 Max inlet pressure for water vapour mbar hPa 50 Max water vapour pumping rate Kg h 0 9 Motor power kW 1 3 0 75 0 75 0 90 0 90 Nominal r p m n min 1400 1700 Noise level UNI EN ISO 2151 K 3dB dB A 62...

Page 9: ...x inlet pressure for water vapour mbar hPa 40 50 Max water vapour pumping rate Kg h 1 2 2 1 Motor power kW 3 1 1 1 35 1 5 1 8 Nominal r p m n min 1400 1700 1400 1700 Noise level UNI EN ISO 2151 K 3dB...

Page 10: ...mbar hPa 2 Max inlet pressure for water vapour mbar hPa 40 Max water vapour pumping rate Kg h 2 9 Motor power kW 3 2 2 2 7 Nominal r p m n min 1400 1700 Noise level UNI EN ISO 2151 K 3dB dB A 68 70 W...

Page 11: ...e with local regulations Do not burn or disperse package components in the environment 4 3 TRANSPORT AND HANDLING HAZARD All transportation lifting and handling operation must be performed by qualifie...

Page 12: ...to install any type of electric or hydraulic motor that has the features described in the table of technical data with flange and shaft corresponding to M100 4 B5 size as per standard IEC 72 WARNING...

Page 13: ...uate for the power absorbed by the pump absorption values are shown on the pump motor rating plate taking into account the environmental conditions of operation HAZARD Always ground the pump Always in...

Page 14: ...ime with the suction inlet completely open WARNING It is advisable not to start the pump more than 12 times per hour to avoid excessive energy consumption and damage to the pump especially for model L...

Page 15: ...n and or repair of any kind except for those listed in this manual Only trained or authorised personnel have the necessary expertise to perform tasks with the technique appropriate for intervention HA...

Page 16: ...e for about 10 minutes first so oil will become thinner stop the pump and disconnect it from the mains undo the oil filler plug get a container large enough to hold all oil and open the oil drainage v...

Page 17: ...l viewer 5503002 Intake filter cartridge 1801019 D V P Vacuum Technology S r l disclaims all responsibility for any deterioration of pump performance or for damages caused due to use of non original s...

Page 18: ...e the air exhaust filter Bearings damaged Contact Service Department Solid particles in the oil Change oil Vanes worn out Contact Service Department C Pump is noisy Motor coupling damaged where presen...

Page 19: ...appear to be faulty due to negligence and or carelessness during use failure to observe the equipment operating instructions lack of maintenance incorrect installation and or maintenance maintenance c...

Page 20: ...D V P Vacuum Technology srl Via Rubizzano 627 40018 San Pietro in Casale BO Italy Tel 39 051 18897101 Fax 39 051 18897170 Email info dvp it Cod 8702037 01 01 2011 R 0 EN...

Reviews: