3.3
DIMENSIONS AND CHARACTERISTICS
3.3.1
Model: LB.5WR
Attachment
point
Motor rating
plate
Motor fan
guard
Drainage
filter valve
Intake
Oil drainage
valve
Oil filler
plug
Air
outlet
Oil
viewer
Information
plate
Reset
pressure
valve
Filter fitting
connection
Terminal
board
Transparent
filter cover
Only on "FKM" versions
LB.5WR
TECHNICAL SPECIFICATIONS
50 Hz
60 Hz
Inlet capacity
m³/h
5
6
Final pressure (Abs.)
mbar - hPa
10
Max inlet pressure for water vapour
mbar - hPa
30
Max water vapour pumping rate
Kg/h
0,11
Motor power
kW (1
~
/ 3
~
)
0,25 / 0,37
0,25 / 0,45
Nominal r.p.m.
n/min
1400
1700
Noise level (UNI EN ISO 2151) (K 3dB)
dB(A)
58
60
Weight
kg (1
~
/ 3
~
)
14,5 / 12,5
Type of oil
cod. DVP
SW60 (BV68)
Oil quantity
dm³
0,25
Pump Intake / Outlet
“G
1/8
Continuous-duty working renge (Abs.)
mbar - hPa
400 ÷ 10
Operating temperature (room temp. 20°C)
°C
65 ÷ 70
70 ÷ 75
Required room temp. for place of installation
°C
12 ÷ 40
Ambient temperature for storage/transport
°C
-20 ÷ 50
MAX humidity / altitude
80% / 1000m a.s.l. *
(*) Please contact the Manufacturer if environmental conditions are different from those prescribed.