DVP LB.40WR Operating And Maintenance Instructions Manual Download Page 6

 

Operating and Maintenance Instructions

 

 

LB.5WR – LC.25WR – LB.40WR – LB.60WR – LC.105WR

 

EN 

 

 

www.dvp.it 

8702037 – 01/01/2011 – R.0 

 

 

Electrical hazard 

Electrical equipment in the pump includes live parts which, upon contact, can cause serious damage to persons and 
property. Any kind of intervention on the electrical system must be performed by qualified personnel.  

 

Fire hazard 

Use of the pump for any uses not provided for or prohibited by this manual as well as a lack of proper maintenance 
can cause malfunction with a risk of overheating and fire. 
In case of fire, do not use water to extinguish the flames, but use dry chemical or CO2 or other means compatible 
with the presence of electrical equipment and lubricants. 
 

2.3 

PICTOGRAMS 

Pictographs  with  the  warning  symbols  and  safety  symbols  for  operators  have  been  applied  to  the  pump.  Read 
carefully and take note of the symbols and their messages before using the pump. 

 

ELECTRICAL HAZARD 
The  pump  is  near  electrical  connections  (protected)  but  where  accidental  contact  can  cause 
electric shock and death. 

 

HOT SURFACE HAZARD 
The  pump  is  close  to  surfaces  with  temperatures  exceeding  70°C  which  may  lead  to  burns  of 
medium severity. 

D.V.P.  Vacuum  Technology  S.r.l  disclaims  any  liability  for  damage  to  persons  or  property  due  to  non-compliance 
with instructions indicated in pictograms or their improper preservation. 
 
 
 

PUMP DESCRIPTION 

 

3.1 

INTENTED USE AND CONTRAINDICATIONS 

 

3.1.1 

INTENTED USE 

The  pumps  described  in  this  manual  are  of  the  rotary  vane  type,  lubricated  with  recirculating  oil.  These  vacuum 
pumps are designed specifically to work with clean air and inert gases in atmospheres with a high amount of water 
vapour. 
Any  other  use  is  prohibited.  The  Manufacturer  is  not  liable  for  any  damage  to  persons  and/or  property  caused  by 
improper pump use or uses of the pump which are not allowed. 
 

3.1.2 

CONTRAINDICATIONS 

 

 

Any  use  other  than  that  for  which  the  pump  was  constructed  is  to  be  considered  an 
abnormal  condition  and  therefore  can  cause  damage  to  the  pump  and  pose  a  serious 
danger to the operator. 

Below  is  a  series  of  operations  involving  improper  use  of  the  pump,  which  are  not  permitted  under  any 
circumstances. 

  Do not use the pump in an explosive or aggressive atmosphere or in an atmosphere with a high concentration of 

dust or oily substances in the air and do not use the pump to pump explosive, flammable or corrosive gases or 
gas that form particles. Using the pump in these atmospheres and with these types of gases can cause injury, 
explosion, fire or serious damage to the pump. 

  Do not use non-original spare parts or parts not provided by the manufacturer. 

  Do  not  use  the  unit  to  pump  solid  materials,  chemicals,  powders,  solvents  or  other  substances  differing  from 

those permitted These types of materials may damage the unit, degrade its performance or reduce its life. 

  do not expose the pump to rain, steam or excessive humidity. 

  Do not place or store near in the proximity of flammable or combustible materials or substances. 

  Do not use the pump as a compressor. 

 

3.2 

FKM VERSION 

This version of the pump is equipped with special technical devices, such FKM seals that allow for use even in the 
presence of some aggressive gases. 

 

WARNING 
Contact the seller to make sure that the pump is suitable for use with a given aggressive gas. 

 

Summary of Contents for LB.40WR

Page 1: ...TECHNOLOGY OPERATING AND MAINT ENANCE INSTRUCTIONS Translation of the original instructions VACUUM PUMPS WITH RECIRCULATING LUBRICATION SYSTEM LB 5WR LC 25WR LB 40WR LB 60WR LC 105WR www dvp it info...

Page 2: ...entele to reach its objectives For this reason our customers are the focus of our attention and we promote the sending of suggestions and or proposals for improvements that could be applied to our pro...

Page 3: ...AND HANDLING 9 4 4 STORAGE 9 4 5 ENVIRONMENTAL CONDITIONS 9 4 6 PUMP INSTALLATION 10 4 7 MOTOR INSTALLATION ONLY LC 105WR 10 4 8 USER SYSTEM 10 4 9 CONNECTION 10 4 9 1 ASSEMBLING THE INTAKE FILTER ON...

Page 4: ...model and serial number year of manufacture date of purchase detail information regarding problems verified 1 3 METHOD OF CONSULTATION For improved understanding of the information provided in this ma...

Page 5: ...other identification plaques D V P Vacuum Technology S r l disclaims any liability for damage to persons or property resulting from improper use of the pump from tampering with its safety apparatus o...

Page 6: ...mps are designed specifically to work with clean air and inert gases in atmospheres with a high amount of water vapour Any other use is prohibited The Manufacturer is not liable for any damage to pers...

Page 7: ...capacity m h 5 6 Final pressure Abs mbar hPa 10 Max inlet pressure for water vapour mbar hPa 30 Max water vapour pumping rate Kg h 0 11 Motor power kW 1 3 0 25 0 37 0 25 0 45 Nominal r p m n min 1400...

Page 8: ...2 Max inlet pressure for water vapour mbar hPa 50 Max water vapour pumping rate Kg h 0 9 Motor power kW 1 3 0 75 0 75 0 90 0 90 Nominal r p m n min 1400 1700 Noise level UNI EN ISO 2151 K 3dB dB A 62...

Page 9: ...x inlet pressure for water vapour mbar hPa 40 50 Max water vapour pumping rate Kg h 1 2 2 1 Motor power kW 3 1 1 1 35 1 5 1 8 Nominal r p m n min 1400 1700 1400 1700 Noise level UNI EN ISO 2151 K 3dB...

Page 10: ...mbar hPa 2 Max inlet pressure for water vapour mbar hPa 40 Max water vapour pumping rate Kg h 2 9 Motor power kW 3 2 2 2 7 Nominal r p m n min 1400 1700 Noise level UNI EN ISO 2151 K 3dB dB A 68 70 W...

Page 11: ...e with local regulations Do not burn or disperse package components in the environment 4 3 TRANSPORT AND HANDLING HAZARD All transportation lifting and handling operation must be performed by qualifie...

Page 12: ...to install any type of electric or hydraulic motor that has the features described in the table of technical data with flange and shaft corresponding to M100 4 B5 size as per standard IEC 72 WARNING...

Page 13: ...uate for the power absorbed by the pump absorption values are shown on the pump motor rating plate taking into account the environmental conditions of operation HAZARD Always ground the pump Always in...

Page 14: ...ime with the suction inlet completely open WARNING It is advisable not to start the pump more than 12 times per hour to avoid excessive energy consumption and damage to the pump especially for model L...

Page 15: ...n and or repair of any kind except for those listed in this manual Only trained or authorised personnel have the necessary expertise to perform tasks with the technique appropriate for intervention HA...

Page 16: ...e for about 10 minutes first so oil will become thinner stop the pump and disconnect it from the mains undo the oil filler plug get a container large enough to hold all oil and open the oil drainage v...

Page 17: ...l viewer 5503002 Intake filter cartridge 1801019 D V P Vacuum Technology S r l disclaims all responsibility for any deterioration of pump performance or for damages caused due to use of non original s...

Page 18: ...e the air exhaust filter Bearings damaged Contact Service Department Solid particles in the oil Change oil Vanes worn out Contact Service Department C Pump is noisy Motor coupling damaged where presen...

Page 19: ...appear to be faulty due to negligence and or carelessness during use failure to observe the equipment operating instructions lack of maintenance incorrect installation and or maintenance maintenance c...

Page 20: ...D V P Vacuum Technology srl Via Rubizzano 627 40018 San Pietro in Casale BO Italy Tel 39 051 18897101 Fax 39 051 18897170 Email info dvp it Cod 8702037 01 01 2011 R 0 EN...

Reviews: