DVP LB.40WR Operating And Maintenance Instructions Manual Download Page 5

 

Operating and Maintenance Instructions

 

EN 

LB.5WR – LC.25WR – LB.40WR – LB.60WR – LC.105WR

 

 

 

 

8702037 – 01/01/2011 – R.0 

www.dvp.it 

 

1.6 

INFORMATION PLATE 

All  pumps  are  equipped  with  an  identification  plate  that  contains  the  manufacturer's  name,  address,  CE  marking 
and technical data of the pump itself. 

VACUUM TECHNOLOGY

 

 

WARNING 
Removing or tampering with the identification plate is strictly prohibited. 

 
 
 

SAFETY 

 

2.1 

GENERAL WARNINGS 

It  is  important  to  read  this  manual  before  performing  any  operation  on  the  pump.  Compliance  with  the  safety 
standards  of  the  country  in  which  the  pump  is  installed  and  requirements  of  qualified  personnel  for  various 
maintenance, use, installation, etc. are recommended throughout the life of the pump. 
The main rules of conduct to be observed for operation at a suitable level of security are the following: 

  Installation, operation, maintenance, etc. operations should always be performed by qualified, trained personnel. 

  Without exception, always wear necessary personal protective equipment. 

  Always perform all cleaning, adjustment and maintenance operations with all power equipment cut off. 

  Do not direct water jets toward electrical parts, even if they are protected by enclosures. 

  Do not smoke during work or maintenance, especially where solvents or flammable materials are being used. 

  Do  not  damage  symbol  plaques  or  pictograms  on  the  pump.  If  they  should  accidentally  become  damaged, 

immediately replace them with other identification plaques.  

D.V.P.  Vacuum  Technology  S.r.l  disclaims  any  liability  for  damage  to  persons  or  property  resulting  from  improper 
use of the pump, from tampering with its safety apparatus or failure to observe operational safety standards. 
 

2.2 

RESIDUAL RISKS 

 

HAZARD 
This  pump  has  been  designed  to  minimise  residual  risks  to  personnel.  We  urge  you,  however,  to 
take the utmost care and attention in carrying out maintenance operations. The confidence gained 
with frequent contact with the pump too often leads users to forget or underestimate risks. 

 

High temperature hazard 
Pump surfaces can exceed a temperature of 70°C. Install the pump in a protected area that is accessible only by 
authorised personnel and only perform operations when the pump is stopped and cooled.  

 

Hazard generated by low pressure 

Avoid  contact  with  pump  intake  attachment  during  operation.  Introduce  air  into  the  suction  circuit  before  any 
intervention. Contact with low pressure points can cause accidents. 

 

Hazard generated by pressure 

The pump tank is pressurised. Do not open and do not leave oil filler or drain plugs open during operation. 

 

Danger from the emission of harmful substances 

Pump outlet air contains traces of oil mist. Ensure compatibility with the working environment. 
Faults or wearing of seals may cause oil lubricant leaks. Avoid dispersion in soil and pollution of other materials. 
Whenever  air  containing  hazardous  substances  are  sucked  in  (i.e.  biological  or  microbiological  agents),  use 
abatement  systems  placed  before  the  vacuum  pump.  Used  oil  must  be  disposed  of  according  to  applicable 
regulations in the country of pump use. 

Summary of Contents for LB.40WR

Page 1: ...TECHNOLOGY OPERATING AND MAINT ENANCE INSTRUCTIONS Translation of the original instructions VACUUM PUMPS WITH RECIRCULATING LUBRICATION SYSTEM LB 5WR LC 25WR LB 40WR LB 60WR LC 105WR www dvp it info...

Page 2: ...entele to reach its objectives For this reason our customers are the focus of our attention and we promote the sending of suggestions and or proposals for improvements that could be applied to our pro...

Page 3: ...AND HANDLING 9 4 4 STORAGE 9 4 5 ENVIRONMENTAL CONDITIONS 9 4 6 PUMP INSTALLATION 10 4 7 MOTOR INSTALLATION ONLY LC 105WR 10 4 8 USER SYSTEM 10 4 9 CONNECTION 10 4 9 1 ASSEMBLING THE INTAKE FILTER ON...

Page 4: ...model and serial number year of manufacture date of purchase detail information regarding problems verified 1 3 METHOD OF CONSULTATION For improved understanding of the information provided in this ma...

Page 5: ...other identification plaques D V P Vacuum Technology S r l disclaims any liability for damage to persons or property resulting from improper use of the pump from tampering with its safety apparatus o...

Page 6: ...mps are designed specifically to work with clean air and inert gases in atmospheres with a high amount of water vapour Any other use is prohibited The Manufacturer is not liable for any damage to pers...

Page 7: ...capacity m h 5 6 Final pressure Abs mbar hPa 10 Max inlet pressure for water vapour mbar hPa 30 Max water vapour pumping rate Kg h 0 11 Motor power kW 1 3 0 25 0 37 0 25 0 45 Nominal r p m n min 1400...

Page 8: ...2 Max inlet pressure for water vapour mbar hPa 50 Max water vapour pumping rate Kg h 0 9 Motor power kW 1 3 0 75 0 75 0 90 0 90 Nominal r p m n min 1400 1700 Noise level UNI EN ISO 2151 K 3dB dB A 62...

Page 9: ...x inlet pressure for water vapour mbar hPa 40 50 Max water vapour pumping rate Kg h 1 2 2 1 Motor power kW 3 1 1 1 35 1 5 1 8 Nominal r p m n min 1400 1700 1400 1700 Noise level UNI EN ISO 2151 K 3dB...

Page 10: ...mbar hPa 2 Max inlet pressure for water vapour mbar hPa 40 Max water vapour pumping rate Kg h 2 9 Motor power kW 3 2 2 2 7 Nominal r p m n min 1400 1700 Noise level UNI EN ISO 2151 K 3dB dB A 68 70 W...

Page 11: ...e with local regulations Do not burn or disperse package components in the environment 4 3 TRANSPORT AND HANDLING HAZARD All transportation lifting and handling operation must be performed by qualifie...

Page 12: ...to install any type of electric or hydraulic motor that has the features described in the table of technical data with flange and shaft corresponding to M100 4 B5 size as per standard IEC 72 WARNING...

Page 13: ...uate for the power absorbed by the pump absorption values are shown on the pump motor rating plate taking into account the environmental conditions of operation HAZARD Always ground the pump Always in...

Page 14: ...ime with the suction inlet completely open WARNING It is advisable not to start the pump more than 12 times per hour to avoid excessive energy consumption and damage to the pump especially for model L...

Page 15: ...n and or repair of any kind except for those listed in this manual Only trained or authorised personnel have the necessary expertise to perform tasks with the technique appropriate for intervention HA...

Page 16: ...e for about 10 minutes first so oil will become thinner stop the pump and disconnect it from the mains undo the oil filler plug get a container large enough to hold all oil and open the oil drainage v...

Page 17: ...l viewer 5503002 Intake filter cartridge 1801019 D V P Vacuum Technology S r l disclaims all responsibility for any deterioration of pump performance or for damages caused due to use of non original s...

Page 18: ...e the air exhaust filter Bearings damaged Contact Service Department Solid particles in the oil Change oil Vanes worn out Contact Service Department C Pump is noisy Motor coupling damaged where presen...

Page 19: ...appear to be faulty due to negligence and or carelessness during use failure to observe the equipment operating instructions lack of maintenance incorrect installation and or maintenance maintenance c...

Page 20: ...D V P Vacuum Technology srl Via Rubizzano 627 40018 San Pietro in Casale BO Italy Tel 39 051 18897101 Fax 39 051 18897170 Email info dvp it Cod 8702037 01 01 2011 R 0 EN...