STOP 

The pump must be stopped by cutting off the power supply.

 

 

WARNING 
If the pump is to be powered off, let it run with closed intake, isolated from the user system, for about 
30 minutes first. This will eliminate any moisture inside the intake chamber and avoid rotor oxidation. 

In the case of long machine downtime, completely empty the pump to avoid hazards of frost during cold weather or 
corrosion due to possible chemical alteration of the stagnant liquid in the pump. 

 
 
 

MAINTENANCE 

 

6.1 

GENERAL WARNINGS 

For good maintenance: 

  Immediately verify the causes of any malfunctions (excessive noise, overheating, etc.); 

  Pay particular attention to safety devices; 

  Make use of all documentation provided by the manufacturer (instruction manuals, wiring diagrams, etc.); 

  Use only appropriate tools and original spare parts. 

In  the  event  of  a  failure  to  understand  the  information  or  procedures  contained  in  this  chapter,  contact  D.V.P. 
Vacuum Technology S.r.l for clarification before proceeding. 

 

HAZARD 
Do  not  perform  any  type  of  operation,  modification  and/or  repair  of  any  kind,  except  for  those 
listed in this manual. 

 

Only  trained  or  authorised  personnel  have  the  necessary  expertise  to  perform  tasks  with  the 
technique appropriate for intervention. 

 

HAZARD 
All maintenance operations must be carried out with the pump disconnected from any power sources. 
Do not operate the pump until it has reached a temperature that is not dangerous for the operator. 

 

HAZARD 
If  pump  maintenance  has  been  performed  in  a  manner  inconsistent  with  instructions,  with          non-original 
spare parts or otherwise so as to impair its integrity or modify its characteristics, D.V.P. Vacuum Technology 
S.r.l will be released from any liability relating to the safety of persons and malfunction of the pump. 

 

6.2 

MAINTENANCE TABLE 

The following table shows all required periodic operations to maintain pump efficiency. 

 

OPERATION TYPE 

FREQUENCY 

OPERATOR 

QUALIFICATION 

Check the oil level and the absence of water vapour condensed in the tank 

24 h 

 

Check the status of the intake filter (only LB.5WR) 

100 h 

 

Change oil 

500 h 

 

Intake filter cartridge replacement (only LB.5WR) 

1000 h 

 

Clean motor fan guard and clean the pump 

1000 h 

 

Change the air exhaust filter 

2000 h 

 

Change vanes 

10000 h 

 

 

Shorter maintenance intervals may be required according to operating conditions (high temperature of intake gases, 
intake gases containing condensable vapours, etc.). 

Summary of Contents for LB.40WR

Page 1: ...TECHNOLOGY OPERATING AND MAINT ENANCE INSTRUCTIONS Translation of the original instructions VACUUM PUMPS WITH RECIRCULATING LUBRICATION SYSTEM LB 5WR LC 25WR LB 40WR LB 60WR LC 105WR www dvp it info...

Page 2: ...entele to reach its objectives For this reason our customers are the focus of our attention and we promote the sending of suggestions and or proposals for improvements that could be applied to our pro...

Page 3: ...AND HANDLING 9 4 4 STORAGE 9 4 5 ENVIRONMENTAL CONDITIONS 9 4 6 PUMP INSTALLATION 10 4 7 MOTOR INSTALLATION ONLY LC 105WR 10 4 8 USER SYSTEM 10 4 9 CONNECTION 10 4 9 1 ASSEMBLING THE INTAKE FILTER ON...

Page 4: ...model and serial number year of manufacture date of purchase detail information regarding problems verified 1 3 METHOD OF CONSULTATION For improved understanding of the information provided in this ma...

Page 5: ...other identification plaques D V P Vacuum Technology S r l disclaims any liability for damage to persons or property resulting from improper use of the pump from tampering with its safety apparatus o...

Page 6: ...mps are designed specifically to work with clean air and inert gases in atmospheres with a high amount of water vapour Any other use is prohibited The Manufacturer is not liable for any damage to pers...

Page 7: ...capacity m h 5 6 Final pressure Abs mbar hPa 10 Max inlet pressure for water vapour mbar hPa 30 Max water vapour pumping rate Kg h 0 11 Motor power kW 1 3 0 25 0 37 0 25 0 45 Nominal r p m n min 1400...

Page 8: ...2 Max inlet pressure for water vapour mbar hPa 50 Max water vapour pumping rate Kg h 0 9 Motor power kW 1 3 0 75 0 75 0 90 0 90 Nominal r p m n min 1400 1700 Noise level UNI EN ISO 2151 K 3dB dB A 62...

Page 9: ...x inlet pressure for water vapour mbar hPa 40 50 Max water vapour pumping rate Kg h 1 2 2 1 Motor power kW 3 1 1 1 35 1 5 1 8 Nominal r p m n min 1400 1700 1400 1700 Noise level UNI EN ISO 2151 K 3dB...

Page 10: ...mbar hPa 2 Max inlet pressure for water vapour mbar hPa 40 Max water vapour pumping rate Kg h 2 9 Motor power kW 3 2 2 2 7 Nominal r p m n min 1400 1700 Noise level UNI EN ISO 2151 K 3dB dB A 68 70 W...

Page 11: ...e with local regulations Do not burn or disperse package components in the environment 4 3 TRANSPORT AND HANDLING HAZARD All transportation lifting and handling operation must be performed by qualifie...

Page 12: ...to install any type of electric or hydraulic motor that has the features described in the table of technical data with flange and shaft corresponding to M100 4 B5 size as per standard IEC 72 WARNING...

Page 13: ...uate for the power absorbed by the pump absorption values are shown on the pump motor rating plate taking into account the environmental conditions of operation HAZARD Always ground the pump Always in...

Page 14: ...ime with the suction inlet completely open WARNING It is advisable not to start the pump more than 12 times per hour to avoid excessive energy consumption and damage to the pump especially for model L...

Page 15: ...n and or repair of any kind except for those listed in this manual Only trained or authorised personnel have the necessary expertise to perform tasks with the technique appropriate for intervention HA...

Page 16: ...e for about 10 minutes first so oil will become thinner stop the pump and disconnect it from the mains undo the oil filler plug get a container large enough to hold all oil and open the oil drainage v...

Page 17: ...l viewer 5503002 Intake filter cartridge 1801019 D V P Vacuum Technology S r l disclaims all responsibility for any deterioration of pump performance or for damages caused due to use of non original s...

Page 18: ...e the air exhaust filter Bearings damaged Contact Service Department Solid particles in the oil Change oil Vanes worn out Contact Service Department C Pump is noisy Motor coupling damaged where presen...

Page 19: ...appear to be faulty due to negligence and or carelessness during use failure to observe the equipment operating instructions lack of maintenance incorrect installation and or maintenance maintenance c...

Page 20: ...D V P Vacuum Technology srl Via Rubizzano 627 40018 San Pietro in Casale BO Italy Tel 39 051 18897101 Fax 39 051 18897170 Email info dvp it Cod 8702037 01 01 2011 R 0 EN...

Reviews: