Manual BAC25A
M-B025CN-300-EN
15
•
STOP I
: The value of charging current which ends the charging process.
•
STOP T
: The period after the charging ends automatically.
The
RIGHT
button is used for navigation, and
UP / DOWN
buttons to set desired values.
NOTE:
Whether a limit is active during the charging test depends on a selected charging
mode. All four limits can be active only in
UU mode
, while the
Boost T
limit
is not
active in the
IU mode
.
In order to activate the limits of
BOOST T
,
STOP U
,
STOP I
and/or
STOP T
(
YES
or
NO
) the
RIGHT
button should be used to move the cursor to the position of the limit status, and using
UP /
DOWN
buttons to select
YES
or
NO
option (Figure 3-8).
The charging process will stop automatically if any of the following parameters reaches its pre-set
value:
STOP U
,
STOP I
and
STOP T (Figure 3-9)
. However, when Boost T parameter is reached in
UU mode
, the BAC25A will switch to Float charging without interrupting the test.
Figure 3-9: STOP messages
The
ENTER
button is used to confirm limit values after the parameters are enabled and set. After
pressing the
ENTER
button, the display switches to the main charging / supply menu (Figure 3-3,
3-5 or 3-7, depending on the previously selected mode).
NOTE:
The
LIMITS
button is active during the charging process. The user can change any
of the displayed parameters (Figure 3-8) without interrupting the test. To do so, the
LIMITS
button should be pressed in order the
LIMITS
menu to be displayed. After
pressing the
ENTER
button, all modifications are accepted in real time and the test
continuous with respect to the new parameters.
3.2.3 Set menu
Pressing the
SET
button on the device the following screen appears on the display: