Operating Manual
© Dürr Systems GmbH
EcoGun AA MAN 2 P
Chyba! Pomocí karty Domů použijte u textu, který se má zde
zobrazit, styl Überschrift 1.
Version: 01
as of: 09/2014
31 / 46
Release packing gland 1248-12.
Unscrew breech ring cap 1240-7 and take off
needle piece complete with springs and
pressing discs pull out backwards.
Unscrew sealing retaining screw by using
socket wrench SW 10 and replace in connection
with sealing ring 1240-25. At the same time
check the ball on needle piece 1248-U3.
Mounting of the parts according to these steps
vice versa.