Operating Manual
© Dürr Systems GmbH
EcoGun AA MAN 2 P
Chyba! Pomocí karty Domů použijte u textu, který se má zde
zobrazit, styl Überschrift 1.
Version: 01
as of: 09/2014
26 / 46
A T T E N T I O N
Danger of material damage and production
interference
Receptacles of sheet metal, high-grade steel or other metals may lead
to damages at the surface of the air cap (electrolysis).
Only use electrically non-conductive receptacles for a cleaning bath.
7.1.2
Notes on the Cleaning
W A R N I N G
Danger due to pressurized lines
Severe injuries may result.
Depressurize all lines before the cleaning.
Purge the spray gun immediately after the use with the cleaning agent
appertaining to the paint. Purge until the cleaning agent emerges
clean from the spray gun.
- Only use cloths and soft brushes.
- Do not use any compressed air. Compressed air can press soilings
into the openings of the spray gun and influence the function.
- Do not bring purging agent on the spray gun with pressure.
- Do not use any abrasive materials (emery, wire wool and so forth).
- At the end of the cleaning, wipe the spray gun dry with a soft cloth.
7.1.3
Lubrication
O ring, needle guiding, needle packing and lever bearing must be
lubricated regularly with silicon-free oil or silicon-free grease.
Pos: 18 /CCP/SG_EcoGun/Eco Gun AS MAN Gravity Feed/09_02_Instand @ 37\mod _1402401244620_20. docx @ 472834 @ 23333 @ 1