Operating Manual
© Dürr Systems GmbH
EcoGun AA MAN 2 P
Chyba! Pomocí karty Domů použijte u textu, který se má zde
zobrazit, styl Überschrift 1.
Version: 01
as of: 09/2014
33 / 46
9
Technical Data
9.1
Connection Values
Maximal admissible air pressure
8 bars
Recommended operating pressure
1.5 - 3.0 bars
Maximally permissible material temperature
when working without gloves
40 °C
Maximally permissible material temperature
when working with gloves
60 °C
Maximal admissible material pressure
250 bars
9.2
Overpressure
For short positive pressures of 10 - 12 bar (143
– 170 psi ) at
the air supply and higher pump pressures (above 250 bar
–
3.556 psi material pressure) there is no danger of the
destruction of the high pressure spray gun.
Positive pressure in the material area are compensated by
automatic release of the paint needle.
Note: Leaving spraying material
9.3
Air Consumption
Air consumption of the high pressure paint spray
gun air regulation Ref. 1248 - U6 is adjusted
fully on max.
see table designation „B “,.
These values below can be reduced by
operating the total air adjustment 1248-U6 by
approx. 80% (i.e. values are than only approx.
20 %)
Circular jet
Flatstream
1,0 bar = 5,0 cbm/h = 84.0 l/min
1,0 bar = 4.3
cbm/h = 72.0
l/min.
2,0 bar = 8.1 cbm/h = 136.0 l/ min.
2,0 bar = 6.9