1018100100L02 1907V005
19
Assembly
8.4 Instructions for use for the pressure vessel (explanation by Be-
hälter-Werk Burgau GmbH)
The pressure vessel must only be used in accordance with the aforementioned intended purpose and
in accordance with the specified technical data. Other forms of use are not permitted for reasons of
safety. The pressure vessel has been designed in accordance with Directive 2014/29/EU and has
been manufactured as a single component without safety equipment for the application area detailed
above.
The unit has been designed for internal pressure loads.
Before commissioning, the vessel must be fitted with the necessary safety equipment such as a pres-
sure gauge and safety equipment designed to protect against overpressure, etc. These parts are not
included in our scope of delivery.
No welding work or heat treatment may be carried out on the pressure-retaining walls of the vessel. It
must be ensured that the internal pressure does not exceed the operating pressure PS specified in
the labelling on the vessel during operation. However, this pressure may be temporarily exceeded by
up to 10%. Vibration stress that would be damaging for the pressure vessel and corrosion on the ves-
sel must be prevented using appropriate measures.
The assembly or installation of the pressure vessel must be carried out in such a way that safe use of
the vessel is ensured (e.g. no rigid connection to the floor or machine base frame without vibration
dampers).
The operating instructions to be provided by the equipment supplier must include the following infor-
mation in accordance with the equipment fitted:
– a) Instructions for draining the condensate
– b) Instructions and information about maintenance to ensure safety of use
The supplier must also specify whether the pressure vessel, when fully equipped for operation, has to
undergo an acceptance test before commissioning. The supplier/owner must observe the laws and
regulations regarding the operation of the pressure vessel that apply in the country of operation.
The design is intended for predominantly static internal pressure loads and covers the following oper-
ating parameters:
1000 load changes from 0 to PS and capable of sustained operation within a pressure fluctuation
range of 2.0 bar (20% PS)
Remarks:
see "8.3 Pressure tank".