Maintenance
104
Operating Instructions 868-M - 01.0 - 12/2020
6.3
Servicing the pneumatic system
6.3.1
Setting the operating pressure
Proper setting
Refer to the
Technical data
) chapter for the permissi-
ble operating pressure. The operating pressure cannot deviate by
more than ± 0.5 bar.
Check the operating pressure on a daily basis.
Fig. 68: Setting the operating pressure
NOTICE
Property damage from incorrect setting!
Incorrect operating pressure can result in damage to the
machine.
Ensure that the machine is only used when the operating
pressure is set correctly.
(1) - Pressure controller
(2) - Pressure gage
②
①
Summary of Contents for 868-M
Page 1: ...868 M Operating Instructions...
Page 6: ...Table of Contents 4 Operating Instructions 868 M 01 0 12 2020...
Page 16: ...Safety 14 Operating Instructions 868 M 01 0 12 2020...
Page 20: ...Machine description 18 Operating Instructions 868 M 01 0 12 2020...
Page 134: ...Setup 132 Operating Instructions 868 M 01 0 12 2020...
Page 136: ...Decommissioning 134 Operating Instructions 868 M 01 0 12 2020...
Page 138: ...Disposal 136 Operating Instructions 868 M 01 0 12 2020...
Page 150: ...Troubleshooting 148 Operating Instructions 868 M 01 0 12 2020...
Page 154: ...Technical data 152 Operating Instructions 868 M 01 0 12 2020...
Page 162: ...Appendix 160 Operating Instructions 868 M 01 0 12 2020 Fig 104 Tabletop drawing 1...
Page 163: ...Appendix Operating Instructions 868 M 01 0 12 2020 161 Fig 105 Tabletop drawing 2...
Page 164: ...Appendix 162 Operating Instructions 868 M 01 0 12 2020 Fig 106 Tabletop drawing 3...
Page 165: ...Appendix Operating Instructions 868 M 01 0 12 2020 163 Fig 107 Tabletop drawing 4...
Page 166: ...Appendix 164 Operating Instructions 868 M 01 0 12 2020...
Page 167: ......