Machine head
Service Instructions 911-211 - 02.0 - 10/2016
42
Disturbances caused by an incorrect setting of the needle guide
• Damage to the needle
• Missing stitches
Fig. 29: Setting the needle guide
To set the needle guide:
1.
Loosen the screws (1).
2.
Remove the throat plate (2).
3.
Rotate the machine to position 1 (
4.
Loosen the screw (4).
5.
Move the needle guide (3) as close as possible against the needle.
6.
Tighten the screw (4).
7.
Check this distance using a piece of paper (5).
(1)
- Screws
(2)
- Throat plate
(3)
- Needle guide
(4)
- Screw
(5)
- Paper
⑤
①
② ③
④