background image

 

 

Instruction Manual 

P-2800 & P-2800D Hand Pumps - V1.1  www.durapac.com 

Page 3 of 12 

 

 

 

Stay clear of loads supported by hydraulics. A cylinder, when used as a load lifting 
device, should never be used as a load holding device. After the load has been raised 
or lowered, it must always be supported mechanically 

 

WARNING: 

 

 

The system operating pressure must not exceed the pressure rating of the lowest 
rated component in the system. Install pressure gauges in the system to monitor 
operating pressure. It is your window to what is happening in the system 

 

 

Always wear appropriate personal protective equipment

 

(PPE) when operating 

hydraulic equipment. The operator must take precaution against injury due to failure 
of the tool or work piece(s) 

 

 

Do NOT

 hold or stand directly in line with any hydraulic connections while pressurising 

 

 

Do NOT

 attempt to disconnect hydraulic connections under pressure. Release all line 

pressure before disconnecting hoses

 

 

 

All personnel must be clear before lowering load or depressurising the system

 

 

 

Do NOT

 attempt to lift a load weighing more than the capacity of the cylinder 

 

IMPORTANT: 

 

 

If at any stage, the safety related decals become hard to read, these must be replaced 

 

 

Minimum age of the operator must be 18 years. The operator must have read and 
understood all instructions, safety issues, cautions and warnings before starting to 
operate the equipment. The operator is responsible for this activity towards other 
persons 

 

 

Do NOT

 lift hydraulic equipment by the hoses or couplers. Use the carrying handle or 

other means of safe transport

 

 

 

Hydraulic equipment must only be serviced by a qualified hydraulic technician. For 
repair service, contact the Durapac authorised service centre in your area. To protect 
your warranty, use only high quality hydraulic oil

 

 

CAUTION: 

 

 

KEEP HYDRAULIC EQUIPMENT AWAY FROM FLAMES AND HEAT.

 Hydraulic fluid can 

ignite and burn. Excessive heat will soften packings and seals, resulting in fluid leaks. 
Heat also weakens hose materials and packings. For optimum performance do not 
expose equipment to temperatures of 65°C (150°F) or higher. Protect all equipment 
from weld spatter 

 

 

No alteration should be made to this device 

3.1

 

Hydraulic Pumps 

 

Do

 use a gauge or other load measuring instrument to verify load 

 

Do NOT

 exceed the rated capacity of the pump or any equipment in the system. 

Burst hazard exists if connection pressure exceeds rated pressure 

 

Do NOT

 operate the system with bent or damaged couplers or damaged threads 

 

Do NOT

 subject the pump and its components to shock loads 

Summary of Contents for P-2800

Page 1: ...186 Granite Street GEEBUNG QLD 4034 Australia sales absoluteequipment com au Phone 61 7 3865 4006 Fax 61 7 3102 6288 Maximum Operating Pressure 700 bar Instruction Manual Two Speed High Volume Hand Pu...

Page 2: ...It is recommended prior to use that an inspection be done by qualified personnel and that any missing or damaged parts decals warning safety labels or signs are replaced with Durapac authorised replac...

Page 3: ...read these must be replaced Minimum age of the operator must be 18 years The operator must have read and understood all instructions safety issues cautions and warnings before starting to operate the...

Page 4: ...in the hose is blocked or reduced Periodically inspect the hose for wear Hose material and coupler seals must be compatible with the hydraulic fluid used Hoses also must not come in contact with corro...

Page 5: ...operation In certain situations the pump handle can kick back Always keep your body to the side of the pump away from the line of force of the handle Do NOT operate a pump that is disconnected from a...

Page 6: ...maintained until the valve is shifted 5 3 3 To allow oil to return to the reservoir shift valve handle to closed position 180o RET 5 4 Double Acting Applications with 4 Way Valve WARNING Operate doubl...

Page 7: ...e clean and free of foreign matter After each use clean couplings and attach dust caps Maintenance is required when wear or leakage is noticed Periodically inspect all components to detect any problem...

Page 8: ...ll cap to operating position 6 2 2 Pump With Double Acting Cylinder B 6 2 2 1 Repeat Steps 6 1 1 to 6 1 3 above if required 6 2 2 2 Position pump at higher elevation than cylinder 6 2 2 3 Put cylinder...

Page 9: ...6 5 1 When not in use depressurise and disconnect the hydraulic pump from the application 6 5 2 Wipe clean thoroughly and store in a clean dry environment Avoid temperature extremes 6 5 3 For transpo...

Page 10: ...ts for P 2800D model only partially Low fluid level in pump reservoir Fill and bleed the system Load above capacity of system Use correct equipment Cylinder piston extends or retracts for P 2800D mode...

Page 11: ...er screw ZAL1287 1 47 Yoke ZAL1198 1 8 Tube connector ZAL1385 2 28 Pump cylinder ZAL1091 1 48 Yoke pin ZAL1156 2 9 Screw ZAL1319 4 29 Bearing ZAL1157 1 49 E ring ZAL1327 2 10 Pump body ZAL1032 1 30 O...

Page 12: ...n ZAL1156 2 9 Screw ZAL1319 4 29 Bearing ZAL1157 1 49 E ring ZAL1327 2 10 Pump body ZAL1032 1 30 O ring ZAL1222 1 50 Rubber ZAL1261 1 11 O ring ZAL1258 2 31 Wiper ZAL1214 1 51 Gasket seal ZAL1712 12 1...