background image

 

 

Instruction Manual 

P-2800 & P-2800D Hand Pumps - V1.1  www.durapac.com 

Page 2 of 12 

 

 

This is a safety alert symbol. It is used to alert you to potential personal injury hazards. 
Obey all safety messages that follow this symbol to avoid injury or death 

1.0

 

Product Information 

DURAPAC – Hand Pumps are engineered to meet Industrial Standards for Performance and Safety.  

The 

P-2800

 is a high flow, 2 speed hand pump with a 

2 way valve

 designed to be used with single 

acting hydraulic equipment. 

The 

P-2800D

 is a high flow, 2 speed hand pump with a 

4 way valve

 designed to be used with double 

acting hydraulic equipment. 

Both models are the ultimate in high performance two speed portable power. They are ideally suited 
to operate high tonnage cylinders where conventional power sources are not available.  Both models 
feature a first stage high flow of 113cc per stroke for fast cylinder advance and retract and a high 
pressure power flow of 4cc per stroke. The pumps are a robustly built, industry proven performer. 

Special skill, knowledge and training may be required for a specific task and the product may not be 
suitable for all jobs. The user must ultimately make the decision regarding suitability of the product 
for any given task and assume the responsibility of safety for all in the work area. Contact a Durapac 
representative if you are unsure of your pumps suitability for a particular application. 

2.0

 

Receiving Instructions 

It is recommended prior to use that an inspection be done by qualified personnel and that any 
missing or damaged parts, decals, warning/safety labels or signs are replaced with Durapac 
authorised replacement parts only. Any hand pump that appears to be damaged in any way, is worn, 
leaking or operates abnormally should be removed from service immediately until such time as 
repairs can be made. Any hand pump that has been or suspected to have been subject to a shock 
load should be removed from service immediately until inspected by a Durapac authorised service 
centre. Owners and operators of this equipment should be aware that the use and subsequent 
repair of this equipment may require specialised training and knowledge. 

3.0

 

Safety 

Save these instructions. For your safety, read and understand the information contained within. The 
owner and operator should have an understanding of this product and safe operating procedures 
before attempting to use this product. Instructions and safety information should be conveyed in the 
operator's native language before use of this product is authorised. Make certain that the operator 
thoroughly understands the inherent dangers associated with the use and misuse of the product. If 
any doubt exists as to the safe and proper use of this product as outlined in this factory authorised 
manual, remove from service immediately. 

 

DANGER: 

 

 

To avoid personal injury keep hands and feet away from work area during operation 

 

 

Do NOT 

handle pressurised hoses. Escaping oil under pressure can penetrate the skin 

causing serious injury. If oil is injected under the skin, see a doctor immediately 

Summary of Contents for P-2800

Page 1: ...186 Granite Street GEEBUNG QLD 4034 Australia sales absoluteequipment com au Phone 61 7 3865 4006 Fax 61 7 3102 6288 Maximum Operating Pressure 700 bar Instruction Manual Two Speed High Volume Hand Pu...

Page 2: ...It is recommended prior to use that an inspection be done by qualified personnel and that any missing or damaged parts decals warning safety labels or signs are replaced with Durapac authorised replac...

Page 3: ...read these must be replaced Minimum age of the operator must be 18 years The operator must have read and understood all instructions safety issues cautions and warnings before starting to operate the...

Page 4: ...in the hose is blocked or reduced Periodically inspect the hose for wear Hose material and coupler seals must be compatible with the hydraulic fluid used Hoses also must not come in contact with corro...

Page 5: ...operation In certain situations the pump handle can kick back Always keep your body to the side of the pump away from the line of force of the handle Do NOT operate a pump that is disconnected from a...

Page 6: ...maintained until the valve is shifted 5 3 3 To allow oil to return to the reservoir shift valve handle to closed position 180o RET 5 4 Double Acting Applications with 4 Way Valve WARNING Operate doubl...

Page 7: ...e clean and free of foreign matter After each use clean couplings and attach dust caps Maintenance is required when wear or leakage is noticed Periodically inspect all components to detect any problem...

Page 8: ...ll cap to operating position 6 2 2 Pump With Double Acting Cylinder B 6 2 2 1 Repeat Steps 6 1 1 to 6 1 3 above if required 6 2 2 2 Position pump at higher elevation than cylinder 6 2 2 3 Put cylinder...

Page 9: ...6 5 1 When not in use depressurise and disconnect the hydraulic pump from the application 6 5 2 Wipe clean thoroughly and store in a clean dry environment Avoid temperature extremes 6 5 3 For transpo...

Page 10: ...ts for P 2800D model only partially Low fluid level in pump reservoir Fill and bleed the system Load above capacity of system Use correct equipment Cylinder piston extends or retracts for P 2800D mode...

Page 11: ...er screw ZAL1287 1 47 Yoke ZAL1198 1 8 Tube connector ZAL1385 2 28 Pump cylinder ZAL1091 1 48 Yoke pin ZAL1156 2 9 Screw ZAL1319 4 29 Bearing ZAL1157 1 49 E ring ZAL1327 2 10 Pump body ZAL1032 1 30 O...

Page 12: ...n ZAL1156 2 9 Screw ZAL1319 4 29 Bearing ZAL1157 1 49 E ring ZAL1327 2 10 Pump body ZAL1032 1 30 O ring ZAL1222 1 50 Rubber ZAL1261 1 11 O ring ZAL1258 2 31 Wiper ZAL1214 1 51 Gasket seal ZAL1712 12 1...

Reviews: