14
Alarm
Code
Title
Suggestion
205
Port 1
over voltage
Ensure that the PV module open-circuit voltage is less than or equal to the maximum
input voltage.
206
(D700-M2 only)
Port 2
over voltage
207
Port 1
under voltage
Ensure that the PV module open-circuit voltage is less than or equal to the maximum
input voltage.
208
(D700-M2 only)
Port 2
under voltage
209
Port 1 no input
Confirm whether this port is connected to the PV module.
If the PV module is connected, please check the DC cable connection between this port
and the PV module.
210
(D700-M2 only)
Port 2 no input
7.3 Troubleshooting List: D1500-M4
Alarm
Code
Title
Suggestion
205
Port 1 & 2
over voltage
Ensure that the PV module open-circuit voltage is less than or equal to the maximum
input voltage.
206
Port 3 & 4
over voltage
207
Port 1 & 2
under voltage
Ensure that the PV module open-circuit voltage is less than or equal to the maximum
input voltage.
208
Port 3 & 4
under voltage
209
Port 1 no input
Confirm whether this port is connected to the PV module;
If the PV module is connected, please check the DC cable connection between this port
and the PV module.
210
Port 2 no input
211
Port 3 no input
212
Port 4 no input
213
Port 1 & Port 2 abnormal
wiring
Check PV input connections.
214
Port 3 & Port 4 abnormal
wiring
Check PV input connections.
7.2 Troubleshooting List: D350-M1 / D700-M2
Installation Manual
Summary of Contents for D1500-M4
Page 8: ...5 5 Installation Planning Installation Manual...
Page 24: ...21 Appendix A Installation Map Template Installation Manual...
Page 25: ...22 Appendix B 120 240 Split phase Electrical Single Line Diagram Installation Manual...
Page 26: ...23 Appendix C 120 208 Three phase Electrical Single Diagram Installation Manual...
Page 28: ...Doc 97010 Installation Manual...