36
––– E 5 –––
SLITTER ERROR
*
*Slitter errors are numbered from 1 to 6.
Cause
•
Slitter sensor is defective
•
Slitter positioning motor is defective
•
Main PWB unit is defective
Problem detected
1. Light did not transmit to the slitter sensor when temporarily shifting inward 8 mm to detect the home position
while the slitter sensor was shielded from light and the command to move the slitter was issued.
2. The slitter did not return to the predetermined position within the specified time period (refer to the table below)
after the command to move the slitter was issued.
Left margin slitter
Right margin slitter
Left center slitter
Right center slitter
OP1 slitter
OP2 slitter
Time until detection
4.5 S
5.5 S
6.0 S
6.0 S
12.0S
6.0S
(OP2: When not installed)
(OP2: When installed)
6.0S (Only when OP2 is installed.)
This image shows the optional 1 slitter sensor.
Angle
Sensor
Connector
LCD message
Slitter
SLITTER ERROR 1
Left margin slitter
SLITTER ERROR 2
Right margin slitter
SLITTER ERROR 3
Left center slitter
SLITTER ERROR 4
Right center slitter
SLITTER ERROR 5
OP1 slitter
SLITTER ERROR 6
OP2 slitter
You can identify the position of the slitter where the error that occurs by looking at the number in the message displayed
on the LCD panel.
Error Messages
Docu Cutter(HCEX) 4_30-52
03.12.8, 3:10 PM
36