roubleshooting - DC545 HCEX
––– E 2 –––
RS232C ERROR
Cause
•
CCD is defective
•
Main PWB unit is defective
Problem detected
1. There was an abnormal transmission between the CCD and the DC-545.
––– E 3 –––
BARCODE ERROR
Cause
•
Bar code being used does not meet specifications
•
CCD is defective
•
Main PWB unit is defective
Problem detected
1. The bar code could not be read even after the paper fed the specified length (50 mm) after the bar code reading
operation started.
––– E 4 –––
REG.MARK ERROR
Cause
•
Reg. mark being used does not meet specifications
•
CCD is defective
•
Main PWB unit is defective
Problem detected
1. The reg. mark could not be read even after the paper fed the specified length (40 mm) after the reg. mark reading
operation started.
2. Mark 1 was less than 4.5 mm.
Error Messages
Docu Cutter(HCEX) 4_30-52