Twin Twist Soft Serve Freezer Model 957RMT
50
184957
NOTE: Contact your authorized H.C. Duke & Son, LLC. Distributor
for instructions prior to warranty compressor replacement.
No air (overrun).
1. Air meter plugged.
1. Clean or replace air meter.
2. Air tube pinched.
2. Replace tube.
Too much air,
overrun too
high – popping
problems.
1. Air meter too large.
1. Install smaller air meter.
2. Air leak between pickup tube and hose.
2. Replace as needed.
3.
Air line hose cracked – sucking air.
3. Replace air line hose.
4. Defective or missing duckbill valve.
4. Replace valve.
Mix shoots out
air meter.
1. Swing Clamp knob loose.
1. Tighten.
2. Transfer hose worn.
2. Replace hose.
3. MTS pressure too high.
3.
Contact your Your local service
company.
PROBLEM
PROBABLE CAUSE
REMEDY