If
PRE-TRIGGER
is enabled in the
PRE-WELD
menu,
then
PRE-TRIGGER
amplitude is available. See Figure
5-9 on the next page.
Press the
AMP
soft key when:
•
PRE-TRIGGER
is enabled for
START OF CYCLE
, and
•
TRIGGER
selection is POWER.
Then the display shown in Figure 5-7 to the right will be
seen.
This menu has
START
as the top soft key. The value last
accessed is highlighted and ready to be changed. In the ex-
ample shown in Figure 5-7, that is
WELD
>
AMPLITUDE
.
For more information about Trigger by Power, refer to our
Application Note 506
on the Dukane website at:
http://
www.dukane.com/us/DL_ApplData.asp
If
AFTERBURST
is enabled in the
POST WELD
menu,
then the
AFTERBURST
soft key is also displayed as
shown in Figure 5-8 to the right. The parameter value last
accessed will be highlighted and will be ready to change.
Figure 5-8
Setting Weld Amplitude with Afterburst
Enabled
Amplitude Range = 20 -100%
NOTE
Figure 5-7
Setting Weld Amplitude
100%
WELD
AMPLITUDE
PRESS ENTER TO ACCEPT
PRESS CANCEL TO ABORT
ONLINE
AMP
PRE
WELD WELD
POST
WELD
LIVE
SETUPS
LIMITS
OPERATE
START
WELD
AMPLITUDE
PRESS ENTER TO CHANGE
ONLINE
AMP
PRE
WELD WELD
POST
WELD
LIVE
SETUPS
LIMITS
OPERATE
START
AFTERBURST
Figure 5-6
Setting Weld Amplitude, Pre-Trigger
Available
WELD
PRE-TRIGGER
Online
100%
AMPLITUDE
AMP
PRE
WELD WELD
POST
WELD
LIVE
SETUPS
LIMITS
OPERATE
Continued from Previous Page
SETUP
SETUP
Page 53
Dukane Manual Part No. 403-594-02
Section 5 - Operation
SETUP