replace or connect the signal
feedback wire.
6.Check whether the supply
power is phase-lacking or
phase opposition.
7.Check whether the AC
electromagnetic contactor
is well.
8.Check whether the outdoor
signal feedback wire in the
terminal inserts firmly, which
is between the indoor PCB
and the display board
E8
display
at off
state
flicker
8/10 SEC
display
at off
state
frost
protection/ov
er heat
protection
1.Check whether the filter of
the indoor unit is dirty or
blocked, and clean if it is dirty
2.Check whether the indoor
fan is running normally, and
replace the motor if it is
abnormal.
3.Check whether indoor pipe