The cross flow fan collides with
the slot basis
Reconfigure.
The noise of the refrigerant
moving.
Readjust the position of the
H&L pressure pipe.
The screw of outdoor unit is loose
and caused the noise and
vibration.
Screw down this screw.
The bearing of cross flow fan
broke.
Replace the bearing.
The cross flow fan collides with
the foam or sponge
Reconfigure or cut out
some foam or sponge
The pipe of outdoor unit contact
with crust
Adjust the pipes and keep
them away more than 3”
from the metallic or plastic
parts
The noise come from synchronous
motor,
stepper
motor,
capacitance, transformer, reactor.
Replace the faulted parts
the indoor and outdoor air
circulation channel is clogged,
which generated noise.
Clear the sundries