Service Manual
43
normal, then the components
or
integrated
circuit
is
damaged, the electric control
board should be replaced.
E4
display
at on/off
state
flicker
4/6 SEC
display
at off
state
outdoor unit
abnormal
1.Check whether the winding
resistance and operation
current of the compressor
are normal.
2.Check whether the high and
low pressure is normal
when the unit is running.
3.Check (whether the coil pipe
sensor is normal) whether the
contact of the inserter on the
circuit board is well, the coil
pipe temperature sensor is
fixed
(whether there is water in
the
fixed
clap)
,
the
evaporation of the indoor unit
is well, the key is to check the
evaporator
temperature
detected by the coil pipe