 Remote control PULT  6204

powered by one  27A 12V battery

 Remote control  PULT 6203 Roll

 Remote control PULT 6203 P (100m)

(Remote control  12bit  PULT 6203**)

Powered by one 12V type A23-5mA battery

DUCATI’s rolling coded remote controls: Pult 6203R; 6203P; 6204

The DUCATI radio rolling coded transmitters, featuring a unique “rolling code” (billions of continuously changing combinations)radio protocol ensure maximum protec-

tion against radio interference.

Frequency:433,92MHz

Each transmitter button is factory programmed with a unique code

Each button can be used to control a different DUCATI rolling coded gate, garage door opener or parking post.

By adding an external DUCATI rolling coded radio receiver (Rixi 6040 or 6043 with display) it is also  possible to control other types of devices of any type and mark by 

a DUCATI rolling coded remote control

To operate your “DUCATI” opener with your DUCATI remote control you must memorize the remote control code on the electronic board of your opener. 

WARNING: Operate adjustments and settings only with garage door or gate in closed postion.

A) To memorize the remote control code inside the electronic panel of the opener:

The door must be closed and idle. 

- Press button P1 on the electronic board. The red LED switches on. 

- Release button P1 and immediately press on the buttons of the remote control that you wish touse to operate the device. Hold the remote button pressed for about 4 

sec. - the LED light  on the electronic board will quickly blink to show the procedure has been completed.

 - Press again the memorized remote control button, the opener will start an manoever

Warning: The memory of the controller can store up to 10-20 codes depending on the model (check the capacity of your memory card. If you need a larger number of 

remote controls is available an optional external receiver (RIXY6040 o RIXI 6043) 

B) To erase the codes from the control board:

To deactivate any unwanted remote, erase its memory from the electronic board of your opener as following (all remote control codes memorized will be delated): 

- The door must be closed and idle.

- Press button P1 for about 20 sec. until the red LED blinks

- Release P1. 

- All remote control codes have been delated.- Reprogram each remote you wish to use following procedure on point A)

Titti i codici sono stati cancellati. Per reinserire nuovamenti i codici del telecomando seguire le operazioni del punto A da 1 a 4.
**

IMPORTANT NOTE:

 Ducati 12 bit Radio remote controls model 6203, are 2 channels 12 bit coded remote controls compatible to 12 bit coded versions devices 

only. Each button can be used to control a different DUCATI rolling coded gate, garage door openerand. The coded trasmitted is a simple 12 bit binary fix code.

6203 12 bit coded remote controls  are compatible only with 12 bit coded electronic boards (12 bit coded electronic board suffix is CTR and not CTH as per rolling 

coded electronic boards).

The 12 bit coded remote control model 6203 is very similar to the rolling coded ones, but has transparent push buttons ( sometimes also transparent case) 

while rolling coded radio 6203R is dark blue with dark blue buttons and  rolling coded model Model 6203P (Enhanced Model 100m) is  dark blue with red buttons

Each remotes has a standard 12 bit BINARY code. 

STANDARD CODE MEMORIZED ON CHANNEL 1 = push button NAMED “OFF” = ON; OFF,ON;OFF;ON;OFF;ON;OFF,ON, OFF;OFF;ON

STANDARD CODE MEMORIZED ON CHANNEL 2 = push button NAMED “ON” = OFF; OFF,ON;OFF;ON;OFF;ON;OFF,ON, OFF;OFF;OFF

A personal code must be programmed to avoid not athorized command by other 6203 remotes.

To program a  personal  code IN YOUR 12 BIT REMOTE CONTROL follow these steps:

1. Simultaneously press the ON and OFF the remote control for about 10 seconds until the LED lights up steady. 

From now on the remote control it is in the programming function; release thebuttons, the LED turns off.

2. Press for about 1-2 seconds the channel you wish to use to command your device ( ON button = channel 1 ; OFF button = channel 2) 

,the LED lights on for about one second.

3. Press the buttons (OFF) (ON) making up your string coding  to 12 pulses ( it is recommended to previously mark your personal code  to be sure have it saved) after  

each pulse wait until the LED gswitches off.

4. On the thirteenth pulse, the remote control will flash to indicate that the programming has been accepted.

To store or delete the electronic card (note: only if series CTR) code, do the above procedure A) as for  for the rolling coded remotes.

Summary of Contents for EVE 01

Page 1: ...Installation manual compliance EN norms SAFE tested certified REV 10 29 11 16 ENG EVE actuators SW actuators HC actuators KONTROL large KONTROl small M A D E I N I T A L Y d u c a t i h o m e i t Watc...

Page 2: ...HC 812 500 PRO 2x 24V HC 812 600 PRO 2x 24V SW 3000 2x 12V SW 7000 2x 12V SW 7000 T 2x 12V SW 7000 T SOLAR 2x 12V EVO 748 2x 12 or 24V EVO 748 T 2x 12 or 24V EVO 748 SOLAR 2x 12 or 24V EVO 748 T SOLAR...

Page 3: ...x 1x 2x 1x 1x 1x 1 x 1x 2x 1x 1x 1x 1 x 1x 2x 1x 1x 1x 1x 1 x 1x 2x 1x 1x 1x 1x 1x 1 x 1x 2x 1x 1x 1x 1x 1x 1x 1 x 1x 2x 1x 1x 1x 1x 1 x 1x 2x 1x 1x 1x 1x 1 x 1x 2x 1x 1x 1x 1x 1 x 1x 2x 1x 1x 1x 1 x...

Page 4: ...l features and usage limits 5 General installation diagram 6 Pillar dimension measure A B gate stop limit 6 HC312 actuator installation limits drawings 8 HC412 actuator installation limits drawings 9...

Page 5: ...FC version only FC version only 3m 350 kg 125 HC518 24V 10 24V 120W 2400 500 2 20 C 60 C FC version only FC version only 3m 450 kg 125 HC 618 11 12V 60W 1200 600 1 5 20 C 60 C FC version only FC vers...

Page 6: ...peed with soft approaching Compatible with solar panel power supply AUTO LOCK SYSTEM Automatic lock the gate wen closed Compatible with emergency battery REVERSAL SYSTEM on ob stacle detection PEDESTR...

Page 7: ...s the gate operator is mounted on the inside of the property and pushes your gate out away from the property Warning only compatible with telescopic tube actuators Check the overall dimen sions before...

Page 8: ...o reverse the polarity of the motor cables when connecting to the electronic board A min 8cm max 14cm B min 8cm max 14cm PULL TO OPEN OPERATION opens towards inside This means the gate operator is mou...

Page 9: ...fixing METRIC CONVERSION 1 cm 1 2 0 3 10 cm 4 12 cm 43 4 4 7 14 cm 51 2 5 5 16 cm 61 5 6 2 18 cm 7 20 cm 77 8 7 87 25 cm 93 4 9 8 28 cm 11 Maximal wing dimension Maximal wing lenght up to 3 5m 11 ft...

Page 10: ...towards the property to open OUTSIDE INSIDE Rear pivot point of gate opener In line with center hinge TAB A 8cm A 10cm A 12cm A 14cm A 16 cm A 18cm A 20cm A 22cm A 24cm A 26cm A 28cm B 8cm 16 sec 97...

Page 11: ...ixing 100 mm 160 mm 920 1520 mm 920 1520 mm METRIC CONVERSION 1 cm 1 2 0 3 10 cm 4 12 cm 43 4 4 7 14 cm 51 2 5 5 16 cm 61 5 6 2 18 cm 7 20 cm 77 8 7 87 25 cm 93 4 9 8 35cm 134 5 13 7 TAB A 8cm A 10cm...

Page 12: ...al dimension A 10 cm A 12cm A 14 cm A 18 cm B 10cm 108 115 120 100 B 12cm 105 112 100 100 B 14cm 103 109 98 B 16cm 101 97 90 B 18cm 97 720 mm 100 mm 160 mm D 6cm D 8 5cm D 10cm D 2 5cm D 2 5cm D 5 4cm...

Page 13: ...cm D 10cm D 2 5cm D 2 5cm D 5 4cm Supplied fixing braket choose the hole most suitable to your gate You can cut the plate if necessary NOT POSSIBLE WITH THIS ACTUATOR MODEL IT REQUIRES TELESCOPIC ACTU...

Page 14: ...5cm D 10cm D 2 5cm D 2 5cm D 5 4cm NOT POSSIBLE WITH THIS ACTUATOR MODEL IT REQUIRES TELESCOPIC ACTUATORS METRIC CONVERSION 1 cm 1 2 0 3 10 cm 4 12 cm 43 4 4 7 14 cm 51 2 5 5 16 cm 61 5 6 2 18 cm 7 P...

Page 15: ...ard TAB A 10 cm A 12cm A 14 cm A 18 cm B 10cm 108 115 120 100 B 12cm 105 112 100 100 B 14cm 103 109 98 B 16cm 101 97 90 B 18cm 97 D 6cm D 8 5cm D 10cm D 2 5cm D 2 5cm D 5 4cm Supplied fixing braket ch...

Page 16: ...o open OUTSIDE INSIDE Rear pivot point of gate opener In line with center hinge D 9 cm D 11cm D 13cm D 15 5 cm 10cm Post fixing Front fixing METRIC CONVERSION 1 cm 1 2 0 3 10 cm 4 12 cm 43 4 4 7 14 cm...

Page 17: ...our gate out away from the property Warning only compatible with telescopic tube actuators Check the overall dimensions before installation Warning remember to reverse the polarity of the motor cables...

Page 18: ...m D 15 5 cm 10cm Post fixing Front fixing TAB A 9 A 11 A 13 A 15 A 17 A 19 A 21 A 23 A 25 B 9 105 21sec 115 22sec 120 23sec 120 23sec 125 23sec 130 25sec 135 26sec 135 26sec 120 23sec B 11 105 21sec 1...

Page 19: ...ator is mounted on the inside of the property and pushes your gate out away from the property Warning only compatible with telescopic tube actuators Check the overall dimensions before installation Wa...

Page 20: ...sec 120 23sec 120 23sec 125 23sec 130 25sec 135 26sec 135 26sec 120 23sec B 11 105 21sec 115 22sec 115 22sec 115 22sec 120 23sec 125 23sec 130 25sec 90 18sec 115 22sec B 13 100 20sec 105 21sec 110 21s...

Page 21: ...4A 16 EVE LOCK optional manual relea se protection by key On board mechanical limits STANDARD manual release STANDARD optional EVE PLAK Electric limits adjustment only available on EVE FC versions DUC...

Page 22: ...22 21 19 A 20A 20B 22 DUCATI HC actuators STANDARD manual release 18A 19 B 18B LIMIT POINT LIMIT POINT Mechanical limits only available on FC versions...

Page 23: ...23A 23B 25A 24 26A 27 STANDARD manual release Mechanical limits only available on FC versions 26B DUCATI SW EVO actuators 25B EVO LOCK optional manual release protection by key LIMIT POINT LIMIT POIN...

Page 24: ...erly installed and is functional Check the structure of the door walls or pillars they must be sound and stable Make sure your door is properly balanced and lubricated An unbalanced door could cause s...

Page 25: ...h a bipolar outdoor cable min 0 35mmq Useful components for an ideal automatic system 1 Control box with containing electronic board with on board radio receiver toroidal transformer inner battery com...

Page 26: ...26B 7 MECHANICAL LIMITS It is reminded that with exhemption in case of use of actuators featured with integrated mechanical or electrical limits it is mandatory to install mechanical gate stop limits...

Page 27: ...f Death Caution it is recommended to prepare a disconnection device to be used in case of emergency Warning the control unit and activation commands must be installed in a not acessible place and at a...

Page 28: ...Black 0 Yellow 12V to be used for 12V motors Black 0 Red 24V to be used for 24V motors TRASFORMER 14 MAIN POWER SUPPLY 230V 110 V The main power supply high voltage 230V 110V on request connection mu...

Page 29: ...wer supply on demand 230V 110V on demand Use on 2 wings gate Use on 1 wing gate Automatic protection fuse Transformer protection fuse 0 8A T 1 2A T Toroidal transformer s Watt 80W Output services 12V...

Page 30: ...opening cycles Red LED visual indicator HOW TO MEMORIZE DELETE REMOTE CONTROL CODE IN THE ELECTRONIC BOARD see also remote control chapter Remote controls setting to syncronize a remote control chann...

Page 31: ...ressure safety system Motor power adjustment Timerized Courtesy light contact Output for elecktrolock 12V dc Safety beam Photocells input Full cycle START NO contact Pedestrian cycle START NO contact...

Page 32: ...o release pressure on wing inghes and ac tuator s gear This function is automatically set in the board To delete this feature proceed as follows press P1 for 1 second the red LED lights Press P2 for a...

Page 33: ...ry output with on boad battery charge management Low battery charge status indication by flashing light Solar panel imput with on board management Low battery charge status indication by LED light Gea...

Page 34: ...e green LED on the control panel is on Meanwhile the acoustic signal must emit a continuous BEEP to show that the solar panel is in a good position If the acoustic signal is intermittent and the red o...

Page 35: ...xternal antenna input Automatic close function timerized 1 100 sec Anti pressure safety system Motor power adjustment Reverse movement on obstacle detection Electric limit switch input Courtesy light...

Page 36: ...DUCATI 7012 in case of standard supply by 230 110 V For different needs first contact our technical department before connecting any non original photocells model electrolock RX photocell model 7012...

Page 37: ...1 on ON use on single wing gate and connect the motor as M1 SWITCH 1 on OFF use on double wing gate SWITCH 2 on OFF Activate SOFT STOP The opener will start at high speed and then slow down the motion...

Page 38: ...RX photocell model 7012 3 COM common connect to n 7 4 FTC photocell contact NC connect to n 6 RX photocell model 7120 1 connect to n 9 2 connect to n 10 TX photocell transmitter same for both 7120 70...

Page 39: ...voltage is lower than 10 5V when powered by battery Green LED if steady on 230 110V powered if flashes slowly battery powered Yellow LED flashes if voltage is lower than 11 5V Blue LED Switches on du...

Page 40: ...phase shift programmed is valid for the closing operation only while the phase shift in the opening is determined by the software and is not editable SOLAR PANEL BACK UP BATTERY POWER SUPPLY CTH48 do...

Page 41: ...ust be closed and idle Press button P1 for about 20 sec until the red LED blinks Release P1 All remote control codes have been delated Reprogram each remote you wish to use following procedure on poin...

Page 42: ...o pier as shown in picture n 2 B2 Press and keep pushed the push button on the original fix code remote control that you wish to duplicate B3 Press and keep pushed the choosen button on GEMINI 6205 af...

Page 43: ...the 4 personal code ENTER hold enter for about 1 5sec at least until the keypad confirms with a beeep Hold the the red LED light on the electronic board will quickly blink to show the procedure has b...

Page 44: ...use the single gate will operate a full cycle Connect connectors 1 2 to the PEDESTRIAN START normally open contact of a DUCATI electronic board to command a partial pedestrian maneuver only 1 wing wil...

Page 45: ...aintains closed or open the circuit ogni switch Each switch is used for the correspondent channel example switch n 1 is used for channel CH1 To sycronize store the remote controls buttons in the radio...

Page 46: ...n number witch is beeing delated is blinking on the display once the code is delated the display switches off Release P2 3 How to delate all stored codes a Push and hold pushed P3 3 until the display...

Page 47: ...bedding or on special support columns The obstacle is detected only if it is located between the infrared light beam between the two photocells The device is composed of a transmitter TX and receiver...

Page 48: ...of the photocell for fixing to the pillar column perfectly align the photocells Place the photocells at a maximum distance of 10m from each other Wiring 1 negative power supply 12 24V AC DC 2 Positive...

Page 49: ...The flashing lights model FLASH 7712 7512 HC7500 12 use a 12V max 10W bulb The flashing lights model FLASH 7724 7524 HC7500 24 use a light bulb max 10W 24V External antennas can be added in case you n...

Page 50: ...to light for more hours per day the levels of autonomy increase exponentially With use of photocells and especially in the case of double pair of photocells SW7120 we recommend the use of a 20W panels...

Page 51: ...th display Ducati radio rolling coded 433 97 MHz storage capacity max 100 codes 1 channel with temporization 0 6 minutes stable bistable STILO 6023 Universal Antenna 433 92MHz fixing bracket 5m cable...

Page 52: ...kers SOLAR SET 1010 SOLAR SET contents 1 x SOLAR1010 10W solar panel 1x BAT1012 12V 7A battery 1 MPBAT battery charger with plug SOLAR SET 1010 SOLAR SET contents 1 x SOLAR1020 20W solar panel 1x BAT1...

Page 53: ...V a c d c NC LASER 100 Pair of universal photocells 12 24V a c d c NC SW 7120 Pair of low consumption photocells compatible with scontrol board CTH44 CTH48 12 24V a c d c NC SW 7012 Pair of univerala...

Page 54: ...54 telescopic actuators HC312 HC412 actuator HC418 D U C A T I S P A R E P A R T S actuator SW400...

Page 55: ...tible to all SW HC actuators HC actuator s spare parts R39 rotor for actuators HC418 HC312 HC412 R76 gearmotor for actuators HC418 HC312 HC412 R4 PA6 gearmotor housing 2 pcs bottom and upper housing f...

Page 56: ...312 R2 400 long screw with roll bearing gear for actuator HC412 HC418 SW010 nut screw with slide front fixing pin for HC418 R37 front cover for HC312 e HC412 R37 front cover for HC418 R11 pins and ciq...

Page 57: ...cluded for SW400 SW400T R39SW rotor for SW400 SW400T R76SW 12V gear for SW400 SW400T SW125 painted aluminium profile for SW400 SW400T SW114 front cover for SW400 SW124 front cover for SW400T Sw110 nut...

Page 58: ...CTURE DESCRIPTION PLBOX control box inner protection compatible with large control box electronic boards CTH42 CTH44 CTH48 PLBOX 812 control box cover bottom Large PLBOX 818 control box cover bottom s...

Page 59: ...to comply EN12453 EN12445 norms and ready to be certified on site by the installers Any new or existing installation requires a declaration of conformity issued by the final installer The installer mu...

Page 60: ...er Intentional or accidental damage as described above are not entitled to warranty 7 There is no liability for a installation periodic inspection maintenance the costs for the installation of the rep...

Page 61: ...de 12 bit while the CTH generation boards use radio rolling coded remote control 30 on board radio hybrid receiver damage Contact the DUCATI official assistance centre send the board to he assistance...

Page 62: ...a non effettua alcun movimento relay stucked contact Ducati s after sale service for under warranty or out of warranty repair one door comple tely open but the second does not perform any move ment yo...

Page 63: ...visit www ducatihome it register your ACCOUNT today you ll get SPECIAL OFFERS DISCOUNTS on extra accessories TAILORED CUSTOMER SERVICE 7 24h NEWSLETTERS and much more...

Page 64: ...d u c a t i h o m e i t Ducati Home Automation Automazione cancelli via Cassani 43036 Fidenza PR ITALY t 39 0524 527967 f 39 0524 591085 mob 39 335 1022019 info ducatihome it...

Reviews: