26
ENGLISH
4) D
EFINITIONS
OF
I
NPUTS
Aerial
Input for the connection of a radio receiving aerial.
5) D
EFINITIONS
OF
O
PTICAL
S
IGNALS
LD1 - Power supply led (red)
It is lit when the electronic card power supply is present.
6) D
EFINITIONS
OF
T
IMERS
Work time
It defines the motor’s work time during the opening or closure phases.
Pause
It defines the duration of the metal rolling shutter’s pause before automatic closure.
7) D
EFINITIONS
OF
JUMPERS
(S
ELECTION
OF
P
ROGRAMS
)
J2
It determines whether the unit will operate in step-by-step or automatic mode
Inserted = Automatic mode Not inserted = Step-by-step logic
J1
It determines whether the unit will operate in opening/closing or cyclical mode.
Inserted = Cyclical mode Not inserted = Opening/closing logic
J3
It determines whether the optical barrier or the wire rib will operate during the metal rolling
shutter’s motion in both directions or during closure only.
Inserted = operates during motion in both directions
Not inserted = operates during closure only