DTI GmbH & Co. KG
Objektgröße / Object Size:
The parameter Object Size allows filtering of small to medium objects. This is abso-
lutely necessary on minerelized soils. Especially for coils of sizes 50 cm to 200 cm an
adaption is necessary. Because of the high penetration depth and because of that
the big volume of soil a rising of the Object Size is mandantory. Without this adaption
the range of value will be overloaded. The range of value 1 – 200 has to be adapted
right at place.
You press ‚F1’ and as an active parameter occurs
Suchempfindlichkeit / Searching Sensitivity:
The Searching Sensitivity is a sensitiv parameter and should only be used for very
low signals. When the audio amplifier is set to maximum and the searching sensitivity
will be rised the searching amplifier will be multiplied by the audio amplifier. This re-
sults in very fast detection signals. The reference (Referenz) has to be made very
carefully. Range of Searching Sensitivity is 1 – 8.
You press ‚F1’ and as an active parameter again occurs the
Tongenerator / Tone Generator.
As being seen out of this discription of parameters some exercise is necessary to
understand the reactions of the detector. You always should first use this parameters
before rising the puls power. Bigger puls power also means bigger penetration depth
and volume of soild under the coil.
You press ‚F5’ and the basic menue option will be displayed.
Seite 14 von 31