Measure Only
Like its name suggests, ”Measure Only” allows you to perform a user measurement without
affecting an existing Anti-Mode calibration. By default the measurement is performed with Anti-
Mode correction enabled and in stereo mode. You can change these defaults from the ”Bypass
AM” and ”Channel” entries in the measurement menu. You can perform a primary and secondary
measurements, and both can be viewed on the Anti-Mode screen.
P
RIMARY
Perform a baseline measurement.
S
ECONDARY
Performs a comparative measurement. The results of Primary and Secondary measurements can
then be viewed together.
The secondary measurement is performed with the same volume setting as the primary
measurement. To start the measurement, increase the volume using the remote or the control
wheel until the same volume as in the primary measurement is reached.
You can abort both primary and secondary measurement by detaching the microphone cable
from Anti-Mode X4.
B
YPASS
AM
Enables or disables Anti-Mode correction during the measurement.
C
HANNEL
Choose Stereo, Left, or Right channel(s) for measurement.
Rev. 1.0
2018-03-14