ACCESSING THE FRONT PANEL CONFIGURATION EDITOR.
•
Ensure the engine is at rest and the module is in STOP mode by pressing the Stop/Reset
button.
•
Press the Stop/Reset
and Info
buttons simultaneously.
•
If a module security PIN has been set, the PIN number request is then
shown :
•
Press the
button the first digit will flash to enable the pin to be entered.
•
Press
(up) or
(down to adjust it to the correct value)
•
Press
(right)
when the first digit is correctly entered. The digit you have just entered will now
show
‘#’
for security.
•
Repeat this process for the other digits of the PIN number. You can press
(left) if you need to move
back to adjust one of the previous digits.
•
When
is pressed after editing the final PIN digit, the PIN is checked for validity. If the number is
not correct, you must re-enter the PIN.
•
If the PIN has been successfully entered (or the module PIN has not been
enabled), the editor is displayed :
EDITING A PARAMETER
•
Enter the editor as described above.
•
Press the
or
to cycle to the section you wish to view/change. Then press
or
to cycle to the parameter within the section you have chosen.
•
To edit the parameter, press
to enter edit mode. The parameter begins to flash to indicate that
you are editing the value.
•
Press the up
or down
buttons to change the parameter to the required value.
•
Press
to save the value. The parameter ceases flashing to indicate that it has been saved.
•
To exit the editor at any time, press and hold the
or
button.
D E E P S E A E L E C T R O N I C S
7 4 1 0 I N S T AL L AT I O N I N S T R U C T I O N S
053-085
ISSUE 3
TYPICAL WIRING DIAGRAM
A larger diagram is available in the operators manual.
Deep Sea Electronics Plc.
Tel:+44 (0)1723 890099
Fax: +44 (0)1723 893303
Email: [email protected]
Web: www.deepseaplc.com
Deep Sea Electronics inc.
Phone: +1 (815) 316-8706
Fax: +1 (815) 316- 8708
TOLL FREE (USA only) : Tel: 1 866 636 9703
Email: [email protected]
Web: www.deepseausa.com
NOTE: When the editor is visible, it is automatically exited after 5 minutes of inactivity to ensure
security.
NOTE: The PIN number is automatically reset when the editor is exited (manually or automatically) to
ensure security.
NOTE: More comprehensive module configuration is possible using the 86xx series PC configuration
software. Please contact us for further details
NOTE: The contents of the tables overleaf may differ depending on the actual module configuration
.
. .
.
DIMENSIONS AND MOUNTING
For flat surface mounting in a Type 1 enclosure
DIMENSIONS
240.0mm x 181.1mm x 41.7mm (9.4” x 7.1” x 1.6”)
PANEL CUTOUT
:
220mm x 160mm (8.7” x 6.3”)