9
4. For each of the 4 function buttons, enter the 2-digit number of the
function you want to select. See the programming worksheets for a list of
function key options.
5. Record your programming choices in the worksheets in the back of the
manual.
6. To exit press [#].
3.4 Identified Wireless Keys
Reporting by the system of openings/closings by individual wireless keys and
command output [
✱
][7] activation by wireless key buttons may be supported on
certain control panels. To do this, the system will reserve access codes 17 – 32
for wireless keys 01-16 respectively. You must program one access code for
each wireless key (using [
✱
][5] access code programming) for this feature to
work correctly.
NOTE: Program these access codes on the system after you have connected
the PC5132-RS to the Keybus (see section 2.4).
Refer to your system Installation Manual for information on access code
programming.
Opening/Closing By Wireless Key Reporting
NOTE: The Identified Wireless Key Opening/Closing option is only available
with PC5010, PC5015, PC5008, PC1565 and PC585 v2.1 and higher.
To enable the reporting of
openings by identified wireless keys:
· Make sure the control panel is v2.1 or higher
· Program a valid access code for each key
· Program an opening reporting code for each key’s access code
· Disable the
Unidentified
Wireless Key Disarming
option in section [017]:
[1]
To enable the reporting of
closings by identified wireless keys:
· Make sure the control panel is v2.1 or higher
· Program a valid access code for each key
· Program a closing reporting code for each key’s access code
· Disable the
Quick Exit
option in section [015]: [4]
Command Output Activation
NOTE: The Identified Wireless Key Command Output Activation feature is only
available with the PC5010, PC5015, PC5008, PC1565 and PC585 v2.0 and
higher.
To enable command output activation by wireless keys, ensure that:
· Make sure the control panel is v2.0 or higher
· Program a valid access code for each key
· Enable the PGM output attribute
Requires Access Code
for each PGM
output programmed as [
✱
][7][1-4] in sections [141] to [154].
W I R E L E S S D E V I C E S