7
W I R E L E S S D E V I C E S
3.2 Enroll Wireless Devices Using Zones (WLS904, WLS905,
WLS906, WLS907 and WLS908)
Enroll wireless devices which use zones (universal transmitters, motion detec-
tors, smoke detectors, and panic pendants):
1. At a system keypad, enter [
✱
][8][Installer’s code] to go the installer’s
programming section.
2. Enter programming section [804].
3. Enter the 2-digit number corresponding to the zone the device is to
occupy ([01] to [32]).
NOTE: Hardwired and wireless devices cannot be assigned to the same zone.
PC5108 zone expander modules occupy zones in 2 groups of 4 (e.g. zones 9-
12 and zones 13-16). None of the zones assigned to a PC5108 module may be
used for wireless devices. For more information on zone assignment, consult
your system Installation Manual.
4. Enter the device’s ESN. The entry
must be six digits. If an older device
with a 5-digit ESN is being enrolled, add the digit [0] to the beginning of
the ESN. (E.g. ESN=21234, enter 021234)
5. The device is now enrolled on the system. Record the serial number and
the assigned zone number in the programming worksheets in the back of
this manual.
6. Continue with steps 3 - 5 until you have enrolled all wireless devices.
7. To exit press [#].
NOTE: The devices will not work properly until you complete zone and partition
programming (see section 4).