S E C T I O N 7
1. When I enter the 2-digit zone number when adding a wireless
device, the keypad gives me a long beep.
You cannot enter ESNs unless a PC5132-RS wireless receiver is connected to
the Keybus. See section 2 for instructions on setting up and wiring the
PC5132-RS module.
2. I have entered the ESN for the device but when I violate the
device, the zone does not show open on the keypad.
Check the following:
• Ensure the ESN has been entered correctly
• Ensure that the zone is enabled for the partition (if partition programming
is used).
• Ensure that the wireless zone is not assigned to a zone used by PC5108
modules.
• Ensure that the zone is programmed for something other than “Null
Operation.” Wireless smoke detectors must be assigned to zones defined
as type [87] or [88].
3. When I try a module placement test I get no result or “Bad”
results.
Check the following (see sections 5.1 and 5.2 for more information on testing
devices):
• Verify that you are testing the correct zone
• Verify that the correct ESN was entered when the device was enrolled
• Verify that the device is in range of the PC5132-RS. Try testing the device
in the same room as the receiver.
• Confirm that the PC5132-RS is properly connected to the Keybus (see
section 2 for PC5132-RS set up and wiring instructions).
• Check that you are testing the zone correctly (see sections 5.1 and 5.2 for
testing instructions)
• Check that the batteries are working and installed correctly.
• Look for large metal objects that may be preventing the signal from
reaching the PC5132-RS.
The device must be located where consistent “Good” results are obtained. If
several devices show “Bad” results, or if panic pendants and wireless keys
operate inconsistently, move the receiver. See section 2.2 for tips on choosing
a mounting location for the PC5132-RS.
4. The LED on the motion detector does not turn on when I walk in
front of the unit.
The LED is for walk test purposes only. See your WLS904 instruction sheet for
walk test instructions.
5. The WLS908 shows a supervisory fault three hours after I enrolled it.
The WLS908 does not transmit a supervisory signal. You must disable supervi-
sion for the zone the WLS908 is assigned to (see section 4.3).