1
SPECIFICATIONS
Control Panel Specifications
21 zones including:
• 16 fully programmable supervised zones (EOL resistors)
• Supervised fire zone
• 1 auxiliary normally open zone
• 3 keypad activated zones
Audible alarm output:
• Bell output
700 mA, fused at 5 Amps, 12 V
DC
unregulated
• Steady or pulsed output
EEPROM memory:
• Does not lose codes or system status on complete AC
and battery failure
Programmable output:
• Transistor switch sinks 50 mA to ground
• Operation controllable through program options
Powerful 1.5 amp regulated power supply:
• 400 mA auxiliary supply, 12 V
DC
unregulated
• Separately fused for battery, keypad/auxiliary supply and
bell output
• Supervision for loss of AC power, low battery
• Internal clock locked to AC power frequency
Switched Smoke Detector Supply Output:
• Controlled from keypad [
Q
][4] command
Battery required:
• 12 volt 4 Ah minimum rechargeable gel-cell or sealed
lead-acid battery
Transformer required:
• 16.5 VAC, 40VA
Dimensions:
• 11” x 11.8” x 3.3” deep (279 x 300 x 84 mm)
Weight:
• 6.5 lbs (3 kg)
Remote Keypad Specifications
(PC3000RK)
• Four wire (QUAD) hook-up and up to 3 keypads per
system
• Built-in piezoelectric buzzer
• Full annunciation of zones and system status
• Nominal current draw 60 mA
• Dimensions 5.5” x 4.5” x 1” deep (140 x 114 x 25 mm)
Output Voltage Specification
Typically, with normal AC in and a fully charged battery, the
output voltage will be 13.8 V
DC
. With AC off and a
discharged battery, the voltage will go to 10 volts. Devices
that require power from the control panel should be capable
of normal operation over the voltage range of 10 to 14 V
DC
.
Digital Communicator Specifications
• 94 reporting codes
• Transmits all 10BPS and 20BPS single line and extended
formats
• Radionics Rounds and Radionics Parity formats
• Sescoa Superfast format
• 3/1, 4/2 and hexadecimal numbers
• DTMF and Pulse dialing
• DPDT line seizure
• True dial tone detection
• Anti-jam feature
• Two telephone numbers and two account codes
• Split reporting of selected transmissions to each
telephone number
Summary of Contents for PC3OOO
Page 1: ...INSTALLATION MANUAL PC3OOO Version 7 51...
Page 40: ...HOOKUP DIAGRAMS 36...
Page 44: ...29000543 R7...