Advanced Programming
48
[338]
Keypad Lockout
maximum number of incorrect access codes has
been entered at a keypad
T/R
(4) 21
JA-00
[339] to
[343]
Closings
system armed (user 01-34, 40-42 indicated)
O/C
(4) A2
CL-UU
[343]
Partial Closing
one or more zones bypassed when system armed
O/C
(4) 7A
CG-ZZ
[343]
Special Closing
Closing (arming) using one of the following meth-
ods: quick arm, auto-arm, keyswitch, function key,
maintenance code, DLS software, wireless key
O/C
(4) AA
CL-00
[344] to
[348]
Openings
system disarmed (user 01-34, 40-42 indicated)
O/C
(4) A2
OP-UU
[348]
Auto Arm Cancellation
automatic arming cancelled by a user
O/C
(4) A5
CE-00
[348]
Special Opening
Opening (disarming) using one of the following
methods: keyswitch, maintenance code, DLS soft-
ware, wireless key
O/C
(4) AA
OP-00
[349] to
[350]
Battery Trouble/Rest.
NT9010 battery is low/battery restored
MA/R
(3) A2
YT-00/YR-00
[349] to
[350]
AC Line Trouble/Rest.
AC power to system is disconnected or interrupted/
AC power restored (both codes follow AC Failure
Comm. Delay.)
MA/R
(3) A1
AT-00/AR-00
[349] to
[350]
Fire Trouble/Rest.
a trouble occurs/restores on a fire zone
MA/R
(3) 73
FT-00/FJ-00
[349] to
[350]
Gen System Trouble/Rest. “Service Required” trouble occurs (view troubles
using [
✱
][2])/trouble restored
MA/R
(3) AA
YX-00/YZ-00
[351]
Line 1 or 2 FTC Restoral
system has restored communications to central sta-
tion on line 1 or 2 (after FTC)
MA/R
(3) 54
YK-00
[351]
Event Buffer is 75% Full event buffer is almost full since last upload
MA/R
(6) 23
JL-00
[351]
DLS Lead In
downloading session start
MA/R
(4) 11
RB-00
[351]
DLS Lead Out
downloading session complete
MA/R
(4) 12
RS-00
[351]
Zone Fault/Rest.
one or more zones have faults/restored
MA/R
(3) 72
UT-ZZ/UJ-ZZ
[351]
Delinquency
programmed amount of time (days or hours) for
delinquency has expired without zone activity, or
without system being armed
MA/R
(4) 54***
CD-00
[353]
Wireless Device Low Bat-
tery Trouble/Rest.
wireless zones, panic pendants, handheld keypads,
wireless keys have low battery/all low batteries
restored
MA/R
(3) 84
XT-00/XR-00
XT-ZZ/XR-ZZ****
[352]
Periodic Test
periodic system test transmission
T
(6) A2
RP-00
[352]
System Test
[
✱
][6] bell/communications test
T
(6) A1
RX-00
Section #
Reporting Code
Code Sent When...
Dialer
Direction*
Automatic
Contact ID
Codes
SIA Auto Rep
Codes**
* A/R = alarms/restorals; T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals;
T = test transmissions
** UU = user number (user01-42); ZZ = zone number (01-32)
***Program the “Fail to close” event code [(4)54] to report either closing or activity delinquency. Make sure your central
station is aware of the application of this reporting code.
****Zones are identified, panic pendants, wireless keys, and handheld keypads are not.
†If unit is to be used in home health care applications, the unit must have medical keys
( )
not auxiliary
(
)
keys.
firealarmresources.com
Summary of Contents for Envoy NT9005EU