[016] Fourth System Option Codes
29
[016] Fourth System Option Codes
1
ON
AC Trouble Displayed
✓
If AC power fails, the condition will be reported to the moni-
toring station and will be indicated as a Trouble condition on
the system keypad.
OFF AC Trouble NOT Displayed
If AC power fails, the condition will be reported, but the Trou-
ble LED will not light on the system keypad. If
[*][2]
is
entered to view the system troubles, Trouble #2 will still be
displayed.
2
ON
Trouble Light Flashes if AC Fails
✓
Whenever AC power is lost from the system, the Trouble LED
will flash in the Ready and Armed modes within 30 seconds
after power is lost. When AC restores, the Trouble LED will
stop flashing within 30 seconds. If enabled, this option will
override the AC display option.
OFF Trouble Light does not follow AC Status
3
ON
Blank Keypad when not used
If no keys are pressed for 30 seconds, all keypad lights turn
OFF and the display will blank until the next keypress, Entry
Delay, audible alarm or keypad buzzer condition.
OFF Keypad always Active
✓
The keypad lights will remain ON at all times.
4
ON
Code Req’d to Remove Keypad Blanking
Before a blanked keypad can be used, a valid access code
must be entered.
OFF No Code Required
✓
Pressing any key on a blanked keypad will remove the
blanking.
5
Future Use
6
ON
Power Save Mode Enabled
If AC power fails, all keypad lights will be shut OFF. The key-
pad lights will come back ON after a keypress, Entry Delay,
audible alarm or keypad buzzer condition except Door
Chime). The keypad lights will return to the off state after 30
seconds of keypad inactivity.
OFF Power Save Mode Disabled
✓
7
ON
Bypass Status displayed While Armed
The Bypass status light will be ON if there are zones bypassed
when the system is armed.
OFF Bypass Status NOT displayed While Armed
✓
The Bypass light will be ON only while the system is disarmed
to indicate that there are bypassed zones on the system.
When the system is armed, the Bypass light will be OFF.
8
Future Use
[017] Fifth System Option Codes
1
ON
WLS Key does not use Access Code
✓
The panel will NOT accept the disarm keycode from an uni-
dentified wireless key. An access code must be used with a
wireless key for proper operation.
OFF WLS Key uses Access Code
The panel will accept the disarm keycode from an unidenti-
fied wireless key, allowing arming/disarming without a code.
☞
Access codes for keys 1-16 are programmed in *Star 5 Func-
tions (
[*][5][17]-[32]
).
2
ON
Auto-arm Schedule in [*][6]
✓
This enables the user to access auto-arming by day in the
[*][6]
menu. When ON, the user may select the day by press-
ing 1 to 7 for Sunday to Saturday.
OFF Auto-arm Schedule in Installer Program-
ming Only
The user can not access auto arming in the
[*][6]
menu.
3
Future Use
4
ON
Double Hit Enabled
When this option is enabled, two alarms from the same zone
will cause the Burglary Verified Police Code to be logged and
transmitted. This feature only applies to zones defined as
Interior, Interior Delay, Interior Stay/Away, or Delay Stay/Away
(PIR zones). This is an extension of the existing Police Code
☞
This feature is directly affected by the Burglary Verified Timer.
OFF Double Hit Disabled
✓
5
ON
Late to Close Enabled
This determines if the
Late to Close
reporting code is sent at
the end of the Auto-arm/Postpone pre-alert. If the auto-arm
toggle option is disabled, the Auto-arm pre-alert must still
occur if there is a time programmed for that day if this option
is enabled. This option does not directly affect the operation
of auto-arm.
This feature is used in installations that require an audible
warning if the panel is not armed by a certain time of day,
Anyone who hears this warning should in turn manually arm,
or contact the central station to let them know why the panel
has not been armed by the programmed time.
OFF Late to Close Disabled
✓
6
ON
Daylight Savings Time Enabled
OFF Daylight Savings Time Disabled
✓
7
Future Use
8
ON
Arm/Disarm Squawk only on Away Arm
If section [014] option [1] is enabled, the bell will squawk dur-
ing
Away
arming
and when disarming from
Away
mode.
OFF
Arm/Disarm Squawk on all Arming types
✓
If section [014] option [1] is enabled, the bell will always
squawk when arming
and disarming.