[009-011] PGM Output Programming
25
01
Fire and Burglary Output -
causes the PGM output to
switch to ground upon any bell activity. The output will be
pulsed or steady depending on the type of bell activity. The
output follows the time programmed for the bell time-out.
Default Attributes:
1,3
ON
2
OFF
See
sections [005] option [4]
and
[014] option [8].
02-04 Not Used
05
Armed Status -
The PGM output switches to ground when
the system is armed (beginning of the exit delay). The output
goes high (open) when the panel is disarmed.
Default Attributes:
1,3
ON
2,5
OFF
06
Ready to Arm -
The PGM output switches to ground as long
as the system is Ready to Arm (all non force-armable zones
on the system are restored). Once an access code is entered
to arm the system and the exit delay begins, the PGM output
is deactivated.
Default Attributes:
1,3
ON
2
OFF
07
Keypad Buzzer Follow Mode -
The PGM output will go low
when the keypad buzzer is activated by the events described
below. The PGM output will go low for as long as the keypad
buzzer is active.
- 24-Hr Supervisory Buzzer Zone
- Auto-arm Pre-alert (1 minute)
- Entry Delay
- Door Chime
Default Attributes:
1,3
ON
2
OFF
08
Courtesy Pulse -
This option provides an output which fol-
lows the entry and exit times. It can be used to turn on a
courtesy light near the exit door for the duration of the entry/
exit times. Upon activation during an entry delay, the output
will remain active for 2 minutes past the entry or exit times to
allow enough time for complete and safe entry or exit to or
from the premises.
Default Attributes:
1,3
ON
2
OFF
09
System Trouble Output (with Trouble Options) -
The
PGM output switches to ground when any
of the selected
Troubles are detected on the system. The output will deacti-
vate when
all of the selected Troubles are restored. The
attributes normally programmed in sections
[141] to [154]
are replaced with the following options.
Default Attributes:
ALL
ON
Attribute
Function
1
2
3
4
5
6
7
8
Service Required
A.C. Fail
Telephone Line Monitoring (TLM) Fault
Communications (Failure to Communicate)
Zone (Fire) Fault
Zone Tamper
Zone Low Battery
Loss of Clock
10
System Event (with Event Options) - Latched System
Event (Strobe).
The PGM output switches to ground when
any
of the selected System Events (Alarms) occur on the sys-
tem. In the Armed state, the output will deactivate only when
an access code is entered to disarm the system. If an alarm
activates this output in the disarmed state, it will deactivate if
a code is entered during bell timeout or if the system arms
after bell timeout. It can be used to indicate that an alarm
has occurred before entering the premises. The attributes
normally programmed in
sections
[141] to [154]
are
replaced with the following options.
Default Attributes:
1-7
ON
8
OFF
Attribute
Function
1
2
3
4
5
6
7
8
Burglary
- Delay, Instant, Interior, Home Away,
and 24-Hr Burglary Zones
Fire - [F]
Key, Fire Zone
Panic - [P]
Key, and Panic
Medical
-
[A]
Key, Medical and Emergency
zones
Supervisory
- Supervisory, Module Supervi-
sory, Auxiliary, Freeze, and Water Zones
Priority
- Gas, Heat, Sprinkler and 24-Hr Latch-
ing Tamper Zones
Holdup
- Holdup Zones and Duress Alarms
Latched
- Follows Output timer.
11
System Tamper (all sources) -
The PGM output switches to
ground when
any
Tamper condition occurs on the system.
The output will deactivate when
all
Tamper conditions on the
system are restored. These tampers include zone tampers
(DEOL), 24-Hr latching tamper zone type and module
tampers.
Default Attributes:
3
ON
12
TLM and Alarm -
The PGM output switches to ground when
there is a Telephone Line fault and any alarm on the system.
In the armed state the output will deactivate only when an
access code is entered to disarm the system. If an alarm acti-
vates this output in the disarmed state, it will deactivate
when the system is armed or the telephone line is restored.
Default Attributes:
3
ON
☞
This output will activate for all silent and audible alarms
except Duress.
13
Kiss-off Output -
The PGM output switches to ground after
the kissoff signal has been received to complete a successful
communication to the central station. The output will switch
to ground for 2 seconds.
Default Attributes:
3
ON
14
☞
Ground Start Pulse -
This option provides a 2-second output
pulse before dialing begins to obtain the dial tone on Ground
Start telephone equipment.
Two 2 Second Pauses must be inserted in the phone number
when using the Ground Start pulse.
Default Attributes:
3
ON
15
Remote Operation -
This option allows the PGM output to
be activated on command through the DLS2002 download-
ing software package.
Default Attributes:
3
ON