47
Appendix A - Reporting Codes
The following tables contain Contact ID and Auto-
matic SIA format reporting codes. For more informa-
tion on reporting code formats, see section [360] to
[381]. For more information on individual reporting
codes, see sections [320] to [353] .
Contact ID
The first digit (in parentheses) will automatically be
sent by the control panel. The second two digits are
programmed to indicate specific information about
the signal.
For example, if zone 1 is an entry/exit point, you could
program the event code as [34]. The central station
would receive the following:
*BURG - ENTRY/EXIT - 1
where the “1” indicates which zone went into alarm.
SIA Format - Level 2 (Hardcoded)
The SIA communication format used in this product
follows the level 2 specifications of the
SIA Digital
Communication Standard
- October 1997. This format
will send the Account Code along with its data trans-
mission. The transmission would look similar to the
following at the receiver:
N Ri01
BA 01
N
= New
Event
Ri01 = Area
Identifier
BA
= Burglary
Alarm
01
= Zone
1
Section #
Reporting Code
Code Sent When...
Dialer
Direction*
Automatic
Contact ID
Codes
SIA Auto Rep
Codes**
[320] to
[323]
Zone Alarms
zone goes into alarm
A/R
(1) 3A
See Table 3
[324] to
[327]
Zone Restorals
alarm condition has been restored
A/R
(1) 3A
[328]
Duress Alarm
duress code entered at keypad
A/R
(1) 21
HA-00
[328]
Opening After Alarm
system disarmed with alarm in memory
A/R
(4) A6
OR-00
[328]
Recent Closing
alarm occurs within two minutes of system arming
A/R
(4) 59
CR-00
[328]
Cross Zone (Police Code)
Alarm
two zones on the system go into alarm during any
given armed-to-armed period (incl. 24Hr zones)
A/R
(1) 4A
BV-00
[329]
[F] Key Alarm/Rest.
Keypad fire alarm (alarm and restore reporting
codes sent together)
A/R
(1) 15
FA-00/FH-00
[329]
[A] Key Alarm/Rest.
Keypad auxiliary or medical alarm† (alarm and
restore reporting codes sent together)
A/R
(1) AA
MA-00/MH-00
[329]
[P] Key Alarm/Rest.
Keypad panic alarm (alarm and restore reporting
codes sent together)
A/R
(1) 2A
PA-00/PH-00
[330] to
[337]
Zone Tamper/Restoral
zone is tampered / tamper condition restored
T/R
(1) 44
TA-ZZ/TR-ZZ
* A/R = alarms/restorals; T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals;
T = test transmissions
** UU = user number (user01-42); ZZ = zone number (01-32)
***Program the “Fail to close” event code [(4)54] to report either closing or activity delinquency. Make sure your central
station is aware of the application of this reporting code.
****Zones are identified, panic pendants, wireless keys, and handheld keypads are not.
†If unit is to be used in home health care applications, the unit must have medical keys
( )
not auxiliary
(
)
keys.