Introduction

1

The 3G3070 is a wireless communicator that sends alarm system information to an SurGard System I, II, 
III, IV or 5 receiver through a 3G (HSPA) or 2G (EDGE/GPRS) wireless network. 

NOTE: The 3G3070 is designed to work with the Contact ID communication format as described in SIA DC-
05 Standard. Before completing the field installation of the alarm monitoring system please ensure com-
munication with the supervising central station is successful by sending several events and getting confir-
mation that they have been received.

Features

• Compatible with 4-digit or 10-digit Contact ID communication format as described in SIA DC-05 

Standard. Example of suitable compatible alarm panels: DSC Models PC1864, PC1832, PC1616, 
PC4020.

• Simulates landline
• Switches automatically to the 3G (HSPA) or 2G (EDGE/GPRS) network in the event of landline trou-

ble (e.g., line down)

• Wireless Signal Indicator
• Four programmable outputs
• Contains one 12V - 1.2 Ah battery
• Case Tamper Output
• Landline overvoltage protection
• Tri-band UMTS/HSPA; Quad-Band GSM/EDGE Radio
• Four programmable inputs
• 3G (HSPA)/2G (EDGE/GPRS) communication with Sur-Gard System I / II / III / IV / 5
• Panel transmission monitoring for up to four phone numbers

Technical Specifications

The input voltage to the 3G3070 can be drawn from the control panel or provided by an external power 
supply rated for the application (external power-limited power source).

NOTE

: The power supply must be Class 2, Power Limited.

Ratings

Power Supply Ratings -  Input Voltage (for long-term operation)

JP3-OFF with internal battery:   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   13.8V

DC

 required 

JP3-ON without internal battery: .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   13.8V

DC

 recommended

NOTE: When the input voltage drops below 13.5V

DC

, the internal battery supplied with the 3G3070 

will not be charged. In order to maintain a charged level for the internal battery, the power supply 
must have a minimum voltage of 13.5V

DC

 to ensure a sufficient battery charge in all conditions of use.

Current Consumption

JP3-OFF with internal battery:   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  120mA*
JP3-ON without internal battery: .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  500mA*

* Plus any current drawn from the 3G3070 AUX+ terminal

Working Voltage Range:

.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 9-14V

DC

 

Battery:   .  .  .  .  .  .  .  sealed, rechargeable type, rated 12V/1.2Ah or 12V/7Ah (for 24hr standby time)
Battery charging voltage: .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  13.5V

DC

Battery charging current: .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   50mA

NOTE: Battery must be replaced every 3-5 years.

Operating frequency:   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  850/1900MHz
Antenna gain:  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   2.0dBi

Environmental Specifications

Operating temperature:   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 0°C-49°C (32°F-120°F)
Humidity:   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .93%RH Maximum (non-condensing) 

Mechanical Specifications

Dimensions (metal enclosure, painted): .  .  .  .  .  .  .  .   138mm x 224mm x 55mm / 5.4” x 8.8” x 2.2”
Weight (without battery):   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  900g / 3.2oz
Internal Event Buffer (communications):  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   256 Events (not viewable)

Simulated Telco Loop specifications (TIP/RING)

On-Hook Voltage:  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 35V

DC

 

Loop Current:   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   25mA
Loop Resistance:  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 600 Ohms 

Summary of Contents for 3G3070

Page 1: ...CATOR INSTALLATION MANUAL V3 6 WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manu facturer The en...

Page 2: ......

Page 3: ...G3070 4 Status LEDS 5 Operating Principles 6 Simulated Landline Mode 6 Panel Transmission Monitoring PTM 6 Wireless Communications Sequence 6 Inputs 6 Outputs 7 Activating the Outputs 7 Swinger Shutdo...

Page 4: ...user to Not attempt to service this product Opening or removing covers may expose the user to dangerous voltages or other risks Any servicing shall be referred to trained service persons only Use aut...

Page 5: ...the control panel or provided by an external power supply rated for the application external power limited power source NOTE The power supply must be Class 2 Power Limited Ratings Power Supply Ratings...

Page 6: ...g over circuit boards Maintain at least 1 25 4mm separation A mini mum 1 4 6 4mm of separation must be maintained at all points between Power Limited wiring and all other non Power Limited wiring Rout...

Page 7: ...5 25 50 ANT 15ft 4 6m 25ft 7 6m or 50ft 15 2m are available The 3G3070 shall be powered from any compatible listed control unit or compatible listed power supply that complies with the ratings specifi...

Page 8: ...building or structure and has been connected to the protective earth ground Descriptions of the terminals can be found in the Connecting the 3G3070 section 5 Reattach the front cover figure 1 item 1...

Page 9: ...below The 3G3070 indicates the status of the highest priority unrestored trouble condition with the corresponding number of flashes of the red LED Once the highest priority trouble condition has been...

Page 10: ...the 3G3070 restarts the error detection sequence before switching The 3G3070 performs this sequence on any phone number that is detected on the line Specific central station phone numbers can be prog...

Page 11: ...it will not restore its state until all the causes of activation are cleared Contact ID Events Description Event Codes INPUT 1 ACTIVATION E110 FIRE ZONE 001 991 INPUT 1 RESTORAL R110 FIRE ZONE 001 99...

Page 12: ...Programming Load option from the menu NOTE Uploading a defaulted communicator will generate an error in the 3G3070 software appli cation Downloading the Device Settings Once programming has been comp...

Page 13: ...54 Failure To Communicate 000 FTC Restoral R 354 Failure To Communicate 000 Send over Cellular If this option is enabled this device will only communicate via cellular network effectively putting the...

Page 14: ...el force dial feature if the control panel used with the 3G3070 does not force dial goes off hook but will not dial if there is no dial tone Status Page This page allows real time monitoring of all de...

Page 15: ...must be active to ensure the signal strength displayed is that of the wireless network provider for which the SIM has access to Panel Programming the control panel should be programmed to communicate...

Page 16: ...the power source connected to the 3G3070 is providing 13 8VDC 120mA and that the battery is fully charged Three Flashes Wireless Network Prob lem Ensure the SIM card has been activated The antenna cab...

Page 17: ...he control panel has a central station phone number programmed Ensure the control panel has the correct account num ber programmed Verify the reporting codes are programmed or the auto Contact ID opti...

Page 18: ...utdown for Telephone Line Monitor TLM transmissions for backup units If the 3G3070 is configured as a backup it can send a maximum of 3 TLM troubles and restorals per day TLM Swinger Shutdown only aff...

Page 19: ...M 1 13 PGM 4 COM TAMPER 3G3070 PGM 3 DC IN NOTES 1 Program the Zone Point as Supervisory type with keypad only annunciation when in Alarm Do NOT use a point that is normally used for 2 Wire Smoke dete...

Page 20: ...ock washer Star washer Cabinet Alarm Control Panel with Dialler Interface Supports Contact ID format Panel Aux Power or External Power Supply 13 8V DC required for normal long term operation Telephone...

Page 21: ...es to the terms of this EULA If the SOFTWARE PRODUCT is an upgrade any transfer must also include all prior versions of the SOFTWARE PRODUCT f Termination Without prejudice to any other rights DSC may...

Page 22: ...d affect the operation of the equipment If this happens the Telephone Company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service Equipment M...

Page 23: ...to adversely affect performance or prevent adequate inspection or testing to verify any war ranty claim Access cards or tags returned for replace ment under warranty will be credited or replaced at DS...

Page 24: ...yco International Ltd will aggressively enforce its intellectual property rights to the fullest extent of the law including pursuit of criminal prosecution wherever necessary All trademarks not owned...

Reviews: