3G Alarm Communicator Installation Manual

Ratings

7

R

ATINGS

H

ARDWARE

 C

OMPATIBILITY

Note for ULC Listed installations:
Products or components of products, which perform communications functions only, shall comply with the requirements applicable to
communications equipment as specified in CAN/CSA –C22.2 No. 60950-1, Information Technology Equipment-Safety - Part 1: Gen-
eral Requirements. Where network interfaces, such as the following, are internal to the subscriber control unit or receiver, compliance
to CAN/CSA –C22.2 No. 60950-1 is adequate. Such components include, but are not limited to: Hubs; Routers; Network interface
devices; Third party communications service providers; Digital subscriber line (DSL) modems; and Cable modems.
Note for UL Listed installations:
Packet switched data network interface equipment, manufactured by other than the burglar alarm equipment manufacturer, that is not
required for the processing of the signals shall be evaluated to the applicable requirements of the Standard for Information Technology
Equipment – Safety – Part 1: General Requirements, UL 60950-1, either as burglar alarm equipment or communication equipment.

S

OFTWARE

 C

OMPATABILITY

The Communicator is compatible with the following software:
• Connect24 Using: Simple Messaging System (SMS) Protocol.
• Connect24 Remote Flash. Using: Internet Protocol (IP) using Trivial File Transfer Protocol (TFTP).

C

ONNECT

24™

1

 A

CCOUNT

 

AND

 SIM 

CARD

 A

CTIVATION

(Before Installation)
Installation of the Communicator requires activation with Connect24 before operation. .

IMPORTANT:

 Prior to installing a 

3G2075 

or

 TL2753G

 Communicator, you will require a Profile Number, Installer ID Number, and

an Installer Password. Perform the following pre installation:
1. Retrieve the installer account and password from the Aurora Technical Services (ATS) group.
2. Call VRU number 1-866-910-3865.
3. Follow the voice prompts to enter the required account information.
4. Power up the communicator. The Communicator will automatically connect and download its programming from Connect24 once

the unit is initialized.

NOTE: 

Following initial installation, you can contact the ATS group to re-configure the Communicator remotely, using the account 

created for this installation.

Before leaving the installation site, the Communicator 3G2075 or TL2753G shall be connected via an APPROVED (acceptable 
to the local authorities) Network Interface Device (NID) (e.g., for UL Installations, UL60950 listed NID). All wiring shall be per-
formed according to the local electrical codes.

Table 3:  Communictor Electrical Ratings

Model

3G2075

Cellular Only

TL2753G

Ethernet and Cellular

Power Supply Ratings

Input Voltage

3.5 / 3.9 / 4.2 VDC (min / NOM / MAX) from the SCW9055/SCW9057 panel

Current Consumption

75 mA

100 mA

Standby Current (@

 

3.7V)

75 mA

100 mA

Alarm (Transmitting) Current)

400 mA @ 3.7V during transmission

Antenna Specifications

Dual band Antenna 

See Table 2 

Environmental Specifications

Operating Temperature

 

0°C - 49°C (32°F- 120°F)

Humidity

5% ~ 85% relative humidity, non-condensing

Mechanical Specifications

Board Dimensions (mm)

109 x 110 

Weight (grams)

60

65

Table 4:  Compatibility

Communicator

Receiver/

ControlPanel 

Description

3G2075

TL2753G

Receiver

SG System I, v1.14+

SG System II, v2.11+

SG-DRL3-IP, v2.3+
SG-DRL4-IP, v1.2+

Control Panel

SCW9055/SCW9057 V1.00 

C

OMMUNICATOR

 P

RE

 I

NSTALLATION

 C

ONFIGURATION

1.

Connect24

DSC

, and 

DLS IV

 are Registered Trademarks of Tyco International Ltd. and its respective Companies. All Rights Reserved.

Summary of Contents for 3G2075

Page 1: ...LARM COMMUNICATOR Warning This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer Installation Manual...

Page 2: ......

Page 3: ...s Sections Ethernet Cellular Programming Options 11 System Options 11 Programming Options 13 Communications Reporting Codes 16 Ethernet Receiver 1 Options 18 Ethernet Receiver 2 Options 18 Ethernet Op...

Page 4: ...response may not occur in time to protect the occupants or their belongings Motion Detectors Motion detectors can only detect motion within the designated areas as shown in their respective installati...

Page 5: ...and return to normal entry NOTE Authorized access to Connect24 3G2075 TL2753G is required to modify any Ethernet Cellular Programming Section Spe cific panel Sections must be configured for proper op...

Page 6: ...ULC INSTALLATION REQUIREMENTS For ULC Residential fire and burglary applications the 3G2075 TL2753G can be used as primary communication channel via either Cellular or Ethernet as applicable or as a b...

Page 7: ...ber Installer ID Number and an Installer Password Perform the following pre installation 1 Retrieve the installer account and password from the Aurora Technical Services ATS group 2 Call VRU number 1...

Page 8: ...des shall be observed and respected during installation INSTALLING CAT 5 CABLE TL2753G ONLY A Category 5 CAT 5 ethernet cable must be run from a source with Ethernet Internet connectivity to the Commu...

Page 9: ...g on to the next number cycling through each of the 4 numbers for a total of 5 times each If all 4 numbers fail the 5 attempts an FTC trouble is displayed on the keypad 4 Panel Sections 301 302 303 an...

Page 10: ...e location is BAD move the SCW9055 SCW9057 to various suitable locations until 3 or more bars are obtained NOTE The communicator is capable of indicating signal strength even without an active SIM but...

Page 11: ...heartbeats to Ethernet Receiver 1 or Cel lular Receiver 1 to test the communications path Use this Section to set the interval time in seconds when heartbeats will be sent to the receivers Valid rang...

Page 12: ...be sent to the programmed receivers based on the settings of the periodic test transmission reporting codes 8 Cellular Low Signal Trouble Default OFF This option masks the Low Signal trouble from the...

Page 13: ...0000 FFFF 013 DLS Outgoing Port Default 0BFA 3066 The DLS Outgoing Port is used for outgoing session to DLS IV after an SMS request has been sent to the Communicator Use this Sec tion to set the value...

Page 14: ...e Time BWST Brazil Western Standard Time PST Philippine Standard Time SLT San Luis Time PIT Pratas Islands PYT Paraguay Time PIT Parcel Island Time JFST Juan Fernandez Island Standard Time MYT Malaysi...

Page 15: ...ca Standard Time PONT Phonpei Standard Time IST Israel Standard Time MAGT Magadan Island Time 3D 3 MSK Moscow Standard Time 5F 11 5 NFT Norfolk Island Time EAT Eastern Africa Time 61 12 NZST New Zeala...

Page 16: ...ent will occur when communications with the panel have been lost for more than 60 seconds 024 Panel Absent Trouble Restore Default FF Program 00 to disable this event or FF to enable This event will o...

Page 17: ...r details on settings NOTE The time interval in minutes between periodic tests is programmed in Section 125 Ethernet and Section 225 Cellular 030 FTC Restore Default FF Program 00 to disable this even...

Page 18: ...ver To configure the device to operate using this Common Receiver Mode functionality program Ethernet Receiver 1 and Cellular Receiver 1 IP address and port number with identical values NOTE When oper...

Page 19: ...lation is located behind a firewall and must be assigned a particular port number as determined by your network administrator Valid range 0000 FFFF NOTE Do not program Ethernet Receiver 1 and Ethernet...

Page 20: ...s all 0 or F will cause a Module Configuration Trouble yellow LED 12 flashes 212 Cellular Receiver 2 DNIS Default 000000 The DNIS is used in addition to the Account Code to identify the Communicator m...

Page 21: ...f minutes See Sec tions 026 029 NOTE Minimum value is 000005 minutes Programming an interval that is less than 5 minutes will disable test transmission 226 Cellular Trouble Delay Default 00 This optio...

Page 22: ...n 008 or assigned by DHCP 990 Boot Loader Version This Section will display the current Boot Loader version of the Communicator 991 Firmware Version This Section will display the current firmware vers...

Page 23: ...ss This Section will display the unique12 digit hexadecimal number assigned as the Media Access Control MAC address of the device SYSTEM RESET DEFAULTS 999 Software Default Default 99 The Software def...

Page 24: ...cate the signal levels with digit 1 and 2 a network status with digit 3 and the trouble status with digit 4 and 5 as indicated in table above For example status code 11000F would display following sta...

Page 25: ...t 06 Ethernet Trouble Check with your ISP to confirm Internet service is active in your area Ensure your Ethernet cable is securely inserted into the RJ45 jack of the Communicator and the Hub Router S...

Page 26: ...evel dBm Signal Level Status Action Required No Signal 0 0 0 108 8 bad Check all antenna connections Confirm 3G service is active in area Relocate Panel 1 Bar 1 4 0 2 108 103 weak Relocate Panel if si...

Page 27: ...range 0000 FFFF ____ ____ ____ ____ 011 Installer Code Default CAFE Valid range 0000 FFFF ____ ____ ____ ____ 012 DLS Incoming Port Default 0BF6 3062 Valid range 0000 FFFF ____ ____ ____ ____ 013 DLS...

Page 28: ...Valid range 000000 999999 minutes ____ ____ ____ ____ ____ ____ CELLULAR RECEIVER 1 OPTIONS 201 Cellular Receiver 1 Account Code Default 0000000000 Valid range 0000000001 FFFFFFFFFE ____ ____ ____ ___...

Page 29: ...____ ____ ____ ____ ____ 989 DNS 2 IP Address ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ 991 Firmware Version ____ ____ ____ ____ ____ ____ ____ ____ 992 Ethernet IP Address ____ ___...

Page 30: ...d materials any upgrades and this EULA and provided the recipient agrees to the terms of this EULA If the SOFT WARE PRODUCT is an upgrade any transfer must also include all prior versions of the SOFTW...

Page 31: ...ed or repaired in such a manner as to adversely affect performance or prevent adequate inspection or testing to verify any warranty claim Access cards or tags returned for replacement under warranty w...

Page 32: ...ada technical specifications were met Certification Number IC 160A 3G255SM This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following tow conditions...

Reviews: