6
M
OUNTING
C
ONSIDERATIONS
The Cellular/Ethernet Communicator is a fixed, wall-mounted unit and shall be
installed in the location specified in these instructions. The equipment enclosure
must be fully assembled and closed, with all the necessary screws/tabs and it must
be secured to a wall before operation.
Internal wiring must be routed in a manner that prevents:
• Excessive strain on wire and on terminal connections,
• Interference between power limited and non power limited wiring,
• Loosening of terminal connections, or
• Damage of conductor insulation.
Warning: Never install this equipment during a lightning storm!
The Installer must instruct the System user on each of the following items:
• This manual shall be used in conjunction with the Alarm controller manual; All the
safety instructions specified within that manual shall be observed.
• Do not attempt to service this product. Opening or removing covers may expose
the user to dangerous voltages or other risks.
• Any servicing shall be referred to trained service person only.
• Use authorized accessories only with this equipment.
Cellular Coverage for Alarm Communicator Operation
The HSPA/3G performance of the
3G2055
and
TL2553G
Alarm Communicators
depends greatly on Cellular network coverage. The SCW (with internal Alarm Com-
municator) should not be mounted in the final location without first ensuring that Cel-
lular radio reception is adequate for communication using the HSPA/3G paths.
Perform the “Communicator Placement Test” on page 15
G
ENERAL
I
NFORMATION
All versions of the HSPA/3G and Ethernet Alarm Communicator, operate on a HSPA/
3G network and are housed inside the Self Contained Wireless (SCW) 9055/9057.
The Communicators use an Internal Antenna only.
Each version of Alarm Communicators covered by this Installation Manual are
described below:
3G2055:
A High Speed Packet Access/Global System for Mobile (HSPA/3G) wireless
Alarm Communicator that sends alarm communication to Sur-Gard System I-IP, II, III
(SG-DRL3IP), IV (SG-DRL4IP) and System 5 (DRL5-IP) central station receivers via a
HSPA/3G digital cellular network.
TL2553G:
Is a dual-path Cellular/Ethernet Alarm Communicator that sends alarm
communication to Sur-Gard System I-IP, II, III, IV and 5 central station receivers
through Ethernet/Internet or a HSPA/3G digital cellular network.
The dual path Communicator can be used as either a backup or primary Communica-
tor. The Communicator supports Internet Protocol (IP) transmission of panel and
internal events over Ethernet/Internet and/or HSPA/3G.
NOTE: For North America the following model names are available:
3G2055-NA
and
TL2553G-NA
.
C
OMMUNICATOR
T
ECHNICAL
S
PECIFICATIONS