27
NOTE: When a valid IP address has been programmed, Ethernet Receiver 1 is
enabled and will communicate events over the Ethernet channel.
Ethernet Receiver 1 and Cellular Receiver 1 may be configured to communicate to
the same central station receiver. To configure the device to operate using this
Common Receiver Mode functionality, program Ethernet Receiver 1 and Cellular
Receiver 1, IP address and port number with identical values.
NOTE: When operating in Common Receiver Mode, Ethernet Receiver 1 account
code will be used for Ethernet and Cellular.
[104] Ethernet Receiver 1 Remote Port
Default (0BF5/3061)
This Section determines the remote port of Ethernet receiver 1. Valid range: 0000 -
FFFF.
[105] Ethernet Receiver 1 Local Port
Default (0BF4/3060)
Use this Section to set the value of the local outgoing port. Set the value of this port
when your installation is located behind a firewall and must be assigned a particular
port number as determined by your central station
system administrator. Valid range: 0000 - FFFF.
[106] Ethernet Receiver 1 Domain Name
Default ( )
Enter the Domain Name as 32 ASCII characters.
i
Programming this Section is
not
permitted on a UL/ULC listed system.
E
THERNET
R
ECEIVER
2 O
PTIONS
[111] Ethernet Receiver 2 Account Code
Default (0000000000)
The account code is used by the central station to distinguish between transmitters.
The account code is used when transmitting heartbeat signals to the central station
receiver. Signals received from the control panel will use the control panel account
number. Valid range: 000000000
1
- FFFFFFFFF
E
. Programming all
0
or all
F
will cause
a Module Configuration Trouble (yellow LED=12 flashes).
NOTE: If both Ethernet Receiver 2 and Cellular Receiver 2 are the same receiver (IP
and port number are identical), Ethernet Receiver 2 account will be used for
Ethernet and Cellular.
[112] Ethernet Receiver 2 DNIS
Default (000000)
The DNIS is used in addition to the account code to identify the Communicator
module at the central station. Valid range: 000000 -
0
99999. Value is entered as
leading
0
followed by the 5-digit DNIS. Format is BCD.
NOTE: Each Ethernet/Cellular receiver must be programmed with a unique DNIS.
[113] Ethernet Receiver 2 Address
Default (000.000.000.000)
Programming the Ethernet receiver 2 IP address with 000.000.000.000 will disable
Ethernet.
Enter the Ethernet receiver 2 IP address. This address will be provided by your central
station system administrator. Format is 4 fields, each field is a 3-digit decimal. Valid
range: 000-255.
NOTE: When a valid IP address has been programmed, Ethernet Receiver 2 is
enabled and will communicate events over the Ethernet channel.
Ethernet Receiver 2 and Cellular Receiver 2 may be configured to communicate to
the same central station receiver.
To configure the device to operate using this common receiver mode functionality,
program the Ethernet Receiver 2 and Cellular Receiver 2, IP address and port number