Page | 62
Dryer Master DM510
Operations Manual
Control Update:
•
Press the
arrow keys
to highlight your
selection.
•
Press
Enter
to select
.
•
Enter the new value and press Enter.
•
Press
‘
Cancel’
to Exit.
Model Beta 1
Control Model Beta 1
Model Beta 2
Control Model Beta 2
Model
Actual
Setpoint
Rate
Control Model
suggested or predicted
rate
Actual rate as displayed
on the main screen
The requested rate in
Manual or Automatic.
Moisture
Control Model
predicted moisture
Actual Moisture as
displayed on the main
screen.
The moisture target or
setpoint.
Model
Difference
Calculated difference
between the control
model predicted
moisture and the actual
moisture
Maximum allowed
difference for ready
function to be initiated
Target
Difference
Calculated difference
between the target or
setpoint and the actual
moisture
Maximum allowed
difference for ready
function to be initiated
Dryer Time in
Minutes
Calculated time in the dryer. This value is derived from the discharge rate
and the dryer volumes and throughput. If this number is wrong correct the
dryer volumes and throughput numbers.
Note:
Do not modify the Model Beta numbers without explicit instructions from the
Dryer Master Support Center
Figure 70
–
Control Update
Control update
Model Beta 1
0.000000750
Model Beta 2
-0.000020000
model
actual
setpoint
Rate
51.57
Moisture
14.50
Model Difference %
2.00
Target Difference %
2.00
Use keys to highlight your choice,
then press ENTER. Or press the number.
Press CANCEL to exit.
,