Dryer Master DM510
Operations Manual
Diagnostics Screen 3:
•
Press the
‘Up arrow’
keys to select the
previous screen
•
Press
‘Cancel’
to return to the ‘Main
Operations Screen’
Control Overview:
•
Press the
‘Up arrow’
key for
‘Control
Update”.
•
P
ress ‘
Down arrow
’ key
for previous screen.
•
Press
‘Cancel’
to return to the
‘Main
Operations Screen’
.
Inlet Calibration Button
No longer used, virtual
Outlet 1 Calibration
Button
Toggles from 0 to 1 when button is pressed. Only active when
sensor is connected and product is present
Outlet 2 Calibration
Button
Toggles from 0 to 1 when button is pressed. Only active when
sensor is connected and product is present.
Local Remote override
Toggles to 1 if override system is installed. Normally not used.
Dryer Fan Status
Toggles to 1 if installed. Normally not used
Dryer Discharge
Toggles to 1 if control, Manual or Automatic, is at Dryer Master.
Dryer Burner Status
Virtual state. Dryer temperature is above burner off temperature
setting in Supervisor setup, control limits.
Dryer Full Status
Virtual state. Generated when product is present at inlet moisture
sensor
Mode Select
Virtual state. 0 = Local, 1 = Manual, -1 = Automatic
Figure 68 - Support System Diagnostics Screen 3
Figure 69
–
Control Overview
Diagnostics Screen 3
CANCEL = exit, Up = prev, Down = next
Inlet Calibration Lamp
0
Outlet 1 Calibration Lamp
0
Outlet 2 Calibration Lamp
0
Alarm Active
0
Local Remote
1
Control Overview
CANCEL = exit, Up = next, Down = prev
Model Beta 1
0.000000750
Model Beta 2
-0.000020000
model
actual
setpoint
Rate
50.94
51.54
51.57
Moisture
14.45
14.37
14.50
Model Difference %
0.09
2.00
Target Difference %
0.13
2.00
Dryer Time (minutes)
69.8