7. INSTRUCTIONS FOR USE 

 

7.1 Start Up 

 

The unit should only be used, opened and repaired by specialized personnel only. 

 

It is prohibited to use the pump if it is submersed in fluid, in dangerous environments or explosive/flammable areas unless 
pre-agreed with supplier and appropriate safety/protection measures have been put in place. 

 

Use gloves and safety glasses as advised in the grease lubricant safety data sheet. 

 

DO NOT use aggressive lubricants on the NBR seals, if in doubt consult DropsA Spa technical office who can offer advice on 
lubricants and provide a pre-approved list of greases. 

 

Ensure proper precaution to keep the pump clean and avoid and potential health hazards. 

 

Always use suitably pressure rated tubing for the lubrication system. 

 

7.2  Action to be taken before start-up. 

 

Check the integrity of the pump. 

 

Refill the tank with suitable lubricant. 

 

Check that the pump is at working temperature and that there are no air bubbles in the pipes. 

 

Check that the electric connection has been carried out correctly (CEI 64/8, IEC 364). 

 

Ensure that the pump is properly connected to the control panel. 

 

 

7.3  Use 

 

Check the data sets imposed. 

 

Press the start button on the machine to which the Sumo pump is connected. 

 

Check pump start-up. 

 

Check  that  the  machine  is  adequately  lubricated  (if  there  are  still  some  doubts  about  its  correct  functioning  you  can 
contact the Dropsa S.p.A Technical Office and request a test procedure). 

 

8. PROBLEMS AND SOLUTIONS 

 

Below is a diagnostic table showing the main faults, the probable causes and the possible solutions. 

In the event of doubts and/or problems which cannot be solved, do not proceed to look for the fault by dismantling parts of 
the machine, but contact the Dropsa Technical Office.

 

 

 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAGNOSTIC TABLE 

FAULT 

 

The pump does not deliver grease or 
does not deliver the correct amount of 
grease  
 
 
 
 
 
The pump does achieve required 
pressure or does not maintain its 
operating pressure. 

CAUSE 

 

The grease level is below minimum. 

 

 
The solenoid valve on the inlet of the 
pump does not vent. 
 
 
 
The fittings are leaving/loose. 
 
 
Regulation of air inlet pressure. 
 
 
 
Internal Check valve is damaged or 
contaminated.  
 

SOLUTION 

 

Add more grease into the reservoir without 
surpassing the MAX level. 
 
Verify it the solenoid vents. Vent the 
solenoid manually and monitor if the 
grease flows out. 

 

 
Tighten the fittings and check for leaks on 
all fittings. 

 

Adjust the air pressure on the inlet of the 
pump taking into account the pressure 
ratio. 
 
Clean or change the valve shown in kit 
3133391. 
  

 

Summary of Contents for LOCOPUMP S3

Page 1: ...CS 5 COMPONENTS 6 UNPACKING AND INSTALLING 7 OPERATING INSTRUCTIONS 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURE 10 DISPOSAL 11 ORDERING INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORTATION 14 OPERAT...

Page 2: ...r and an adjustable delivery kit Loading connection is completed of a filter guaranteeing the input of clean lubricant into the reservoir It s possible to use a filtered clean grease return in the res...

Page 3: ...rease output The level sensor is and electric contact that indicates that the pump has reached its low level of grease It s possible to set it to either Normally Closed or Normally Open see drawing fo...

Page 4: ...hread that allows interfacing with up to two 400cc lubricant cartridges High Reliability is guaranteed by the use of hardened steel in the construction in all the pumping element components and the pu...

Page 5: ...LET CONNECTION The hydraulic connection of the pump is on the front face of the pump It is a standard 1 4 BSP see drawing in chapter 12 6 5 AIR CONNECTION ON PUMP Use an 1 8 BSP connection fitting It...

Page 6: ...ss the start button on the machine to which the Sumo pump is connected Check pump start up Check that the machine is adequately lubricated if there are still some doubts about its correct functioning...

Page 7: ...le All components must be clean with cleaning fluid and lubricated before re assembly Periodically it is necessary to check CHECK TOTAL NUMBER OF PUMP CYCLES The lubrication status 100 Lubricant level...

Page 8: ...future maintenance increase the spaces indicated by at least 100 mm 2 Kg 0 5 Kg H 433 272 AIR INLET G1 8 BSP Compression fitting for 6 pipe LUBRICANT OUTLET G1 4 BSP LUBRICANT INLET Valved Greaser UNI...

Page 9: ...eans of compiling the checklists already made available and contained in the technical file Two types of lists were used List of dangers section from UNI EN ISO 14121 1 relating to UNI EN ISO 12100 Ap...

Reviews: