background image

7/9 

 

9. MAINTENANCE PROCEDURES 

 

Ensure the pump is positing so that it can be verified easily. 
Ensure you have necessary personal protective equipment to avoid any contact with the grease. 

 

The pump undergoes severe factory testing therefore no maintenance is forecasted with the pump.  

DropsA  recommends  the  use  of  lubricants  that  are  free  of  any  impurities  as  well  as  a  regular  cleaning  of  the  pump’s 
components. 
 

The pump is dismantled as follows: 
 
1.

 

Before removing the reservoir is must be completely emptied of lubricant.

 

2.

 

Disconnect the air inlet connection. 

3.

 

Disconnect all tubing on the pump. 

4.

 

Loosen the screws on the lid, remove the reservoir 

taking ABSOLUTE care of the spring inside the reservoir  ( it may still be 

under tension – if so remove more lubricant.)

 

5.

 

Remove the pump and any filters if fitted. 

6.

 

Unscrew the plug on the pneumatic pump body, 

be careful 

of the load on the internal spring. At this point you can remove 

the internal components of the pump body. 

 

At this point all components are loose and allow the cleaning and verifying of each component possible. 

All components must be clean with cleaning fluid and lubricated before re-assembly. 
 

Periodically it is necessary to check: 
 

 

CHECK 

TOTAL NUMBER OF PUMP CYCLES 

The lubrication status 

100 

Lubricant level 

200 

Clean refilling filter  

400 

Clean bottom of reservoir if deposits have formed. 

600 

 

The  machine  does  not  require  any  special  equipment  for  any  checking  and/or  maintenance  activity,  however  the 
recommendation is to use suitable equipment which is in a good condition (according to current regulation) in order to avoid 
causing damage to persons or machine parts. 
Make sure that the electric and hydraulic supply has been disconnected before carrying out any maintenance intervention. 

 
 

10. DISPOSAL 

 

In the course of machine maintenance, or if the machine is scrapped, do not dispose of polluting parts into the environment. 
Refer  to  local  regulations  with  regard  to  their  correct  disposal.  When  scrapping  the  machine  the  identification  plate  and  any 
other documents must be destroyed. 

 
11. INFORMATION ABOUT ORDERING  

 

PART NUMBER 

FEATURES 

3413050 

Pneumatic pump R=50:1 Reservoir 2 Kg (4,4 lb) 

3413060 

Pneumatic pump R=50:1 Reservoir 0.5 Kg (4,4 lb) 

3133936 

Replacement gaskets Kit  

3133390 

Adjustable pump output kit 

3413050 C 

Preloaded pneumatic pump R=50:1 Reservoir 2 Kg (4,4 lb) 

 

Summary of Contents for LOCOPUMP S3

Page 1: ...CS 5 COMPONENTS 6 UNPACKING AND INSTALLING 7 OPERATING INSTRUCTIONS 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURE 10 DISPOSAL 11 ORDERING INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORTATION 14 OPERAT...

Page 2: ...r and an adjustable delivery kit Loading connection is completed of a filter guaranteeing the input of clean lubricant into the reservoir It s possible to use a filtered clean grease return in the res...

Page 3: ...rease output The level sensor is and electric contact that indicates that the pump has reached its low level of grease It s possible to set it to either Normally Closed or Normally Open see drawing fo...

Page 4: ...hread that allows interfacing with up to two 400cc lubricant cartridges High Reliability is guaranteed by the use of hardened steel in the construction in all the pumping element components and the pu...

Page 5: ...LET CONNECTION The hydraulic connection of the pump is on the front face of the pump It is a standard 1 4 BSP see drawing in chapter 12 6 5 AIR CONNECTION ON PUMP Use an 1 8 BSP connection fitting It...

Page 6: ...ss the start button on the machine to which the Sumo pump is connected Check pump start up Check that the machine is adequately lubricated if there are still some doubts about its correct functioning...

Page 7: ...le All components must be clean with cleaning fluid and lubricated before re assembly Periodically it is necessary to check CHECK TOTAL NUMBER OF PUMP CYCLES The lubrication status 100 Lubricant level...

Page 8: ...future maintenance increase the spaces indicated by at least 100 mm 2 Kg 0 5 Kg H 433 272 AIR INLET G1 8 BSP Compression fitting for 6 pipe LUBRICANT OUTLET G1 4 BSP LUBRICANT INLET Valved Greaser UNI...

Page 9: ...eans of compiling the checklists already made available and contained in the technical file Two types of lists were used List of dangers section from UNI EN ISO 14121 1 relating to UNI EN ISO 12100 Ap...