16
9.4.1 BASE MENU
The
BASE MENU
allows the operator to carry out a quick initial system setting.
In this menu are shown only the basic parameters relating to the type of system set, with the parameters in the advanced
menu.
9.1.1.
ADVANCED MENU
The
ADVANCED MENU
allows the installer a quickly configure the system.
This menu also displays the parameters of the basic menu.
The main parameters to configure a system are:
Lubrication
Range
Inlet 1
Inlet 2
By changing the value of any parameter it is possible that other parameters will be shown in red colors "Parameter error”.
"Parameter error" means that the combination of parameters is not correct and consequently the pump does not start the
lubrication cycle.
To resolve this error you need to change the parameter (s) with a correct combination of parameters.
9.1.1.1.
PARAMETERS RELATING TO THE OPERATING MODE
The following table shows the operating parameters relating to the operating modes and possible settable values.
Name
Full name
Default value
Description
Values
Lubrication
Lubrication
PS/SEP
Lubrication phase
adjustment
PS/SEP
Pulse counting
Rotation
Time
External enabling
Range
Lubrication range
Time
Lubrication range
adjustment
Time
Pulse counting
Time&Pulses
Pulses &TOut
Inlet 1
Inlet 1
SEP/PROX
Type of sensor connected
to input 1
Disconnect
PS
SEP/PROX
Pulse counting
Suspension
External enabling
Inlet 2
Inlet 2
Stand by
Type of sensor connected
to input 2
Disconnect
PS
SEP/PROX
Pulse counting
Suspension
External enabling