19
9.4.2.3 OTHER ADVANCED PARAMETERS
The following table illustrates the remaining Advanced parameters and possible values that can be set.
NAME
FULL NAME
DEFAULT
VALUE
DESCRIPTION
VALUES/INTERVAL
Suspension
Suspension
Always
Phase in which suspension
is enabled
Paused
During lubrication
Always
Suspension contact
Suspension contact
Normal. Open
Suspension signal type
Normal. Open
Normal. Closed
Starting from
Starting from
Lubrication
Phase performed when the
pump is started
Lubrication
Non-Lub. Cycle
Last Status
Number of Prelub.
Cycles
Number of Prelub. Cycles
0
Number of cycles during
the pre-lubrication phase
0 - 250
Deact. Min. Lev.
Deactivate minimum level
☐
Alarm deactivation
corresponding to
minimum level
Ticked
☐
Not ticked
Lub. status output
Lubrication status output
Lubr.(fixed) e
Pause(lamp)
Conduct of lubrication
status output
Only lubrication
Lub. (fixed) and Pause (lamp)
Lub. status output
Lubrication output status
contact
Type P
Lubrication Status Output
signal type
Type N
Type P
Alarm status output
Alarm status output
Alarm (fixed)
and Warn.
(lamp)
Conduct of alarm status
output
Alarm only
Alarm coding
Alarm and Warn. coding
Alarm (fixed) and Warn. (lamp)
Alarm status output
Conduct of alarm status
output
Type P
Alarm Status Output
signal type
Type N
Type P
Tank type
Tank type
Unconfigured
Tank type installed on
pump
(Note: once setting is no
longer displayed)
Unconfigured
Follower plate
Cart. 400cc
Cart. 700cc
9.4.3 SYSTEM MENU
Allows setup of all the general
data of the pump (e.g. date, time, FW update etc.)
This menu lets you set up 3 types of password:
-
Base menu password -> access ONLY to the base menu programming
-
Advanced menu password -> access BOTH to the base menu AND to the
advanced menu programming
-
System menu password -> access to all programming levels